Cov khoom

KYN28-24 Cov Khoom Siv Hluav Taws Xob Hluav Taws Xob Sab Hauv Tsev
2.Rated Zaus: 50Hz
3.Rated tam sim no: 630/1250/1600/2000/2500/3150/4000A
4.Installation method: pem teb-mounted los yog ntsia rau hauv lub prefabricated sab nraum lub thawv
5.Kev siv ib puag ncig: sab hauv tsev
6. Cov qauv kev ua raws cai: GB / T 3906, IEC 298, DL 404, thiab lwm yam
KYN28-24 Sab Hauv Tsev Cov Khoom Siv Hluav Taws Xob Hluav Taws Xob Hluav Taws Xob Hluav Taws Xob (tom qab no hu ua KYN28-24 switchgear) yog tsim rau peb-theem AC 50HZ, 24kV ib lub tsheb npav thiab ib lub busbar segmented fais fab tuag, thiab muaj "tsib tsib kev tiv thaiv" functions. Qhov tshem tau ntawm lub switchgear tuaj yeem nruab nrog lub tshuab nqus tsev nqus hluav taws xob, lub tsheb sib cais thiab lwm yam khoom siv.
Khoom Specifications
|
Tsis muaj. |
Lub npe |
Chav tsev |
Cov ntaub ntawv |
|
1 |
Rated Voltage |
kV ua |
24 |
|
2 |
Rated Zaus |
Hz |
50 |
|
3 |
Rated tam sim no |
A |
630/1250/1600/2000/2500/3150/4000 |
|
4 |
Rated fais fab zaus tiv taus voltage |
kV ua |
79 nrug) |
|
5 |
Rated xob laim impulse withstand voltage |
kV ua |
145 (Common tus nqi) / 125 (Ntawm qhov kev ncua deb) |
|
6 |
Rated luv-circuit breaking tam sim no |
kA |
20/25/31.5/40 |
|
7 |
Rated-luv-circuit ua tam sim no (peak) |
kA |
50/63/80/100 |
|
8 |
Rated tiv taus tam sim no (peak) |
kA |
50/63/80/100 |
|
9 |
Rated duration ntawm luv luv Circuit Court |
s |
4 |
|
10 |
Kev khiav hauj lwm cycles ntawm ntsuas luv luv-circuit breaking tam sim no |
Sijhawm |
E2 |
|
11 |
Kev tiv thaiv qib |
Sab nrauv npog IP4X; Chav chav IP2X |
Khoom zoo
KYN28-24 Sab Hauv Tsev Armored Metal-Enclosed Switch Equipment muaj ntau yam zoo:
Zoo meej qauv:
Lub txee yog tag nrho sib sau ua ke thiab muaj ntau lub folding qauv nrog aluminium-zinc phaj.
Kev saib xyuas yooj yim thiab yooj yim:
Lub txee yog nruab nrog lub hauv paus trolley Circuit Court breaker, uas yooj yim rau kev tshuaj xyuas thiab tu.
Kev siv ntau yam:
Cov khoom lag luam npog ntau yam, los ntawm qhov ntsuas tam sim no 630A mus rau qhov ntsuas tam sim no 4000A, thiab los ntawm kev ntsuas tam sim no 20KA txog 40kA; npog -40 degree ~ 40 degree siv ib puag ncig; lub Circuit Court breaker nyob rau hauv lub txee yuav nruab nrog domestic thiab txawv teb chaws tshem tawm lub tshuab nqus tsev Circuit Court breakers;
Muaj kev nyab xeeb heev:
Lub txee tau muab faib ua plaub qhov kev ywj pheej, uas muaj kev nyab xeeb thiab tsim nyog;
Perfect tsib-tiv thaiv interlocking:
a. Thaum lub Circuit Court breaker thiab qhov hloov hauv av nyob rau hauv txoj hauj lwm qhib, lub trolley tuaj yeem txav los ntawm qhov chaw sim / cais mus rau qhov chaw ua haujlwm. Nyob rau hauv lub xeev qhib no, rov qab txav kuj tseem tuaj yeem ua tau (kev sib cuam tshuam tshuab).
b. Lub Circuit Court breaker tsuas yog kaw thaum lub trolley yog kiag li nyob rau hauv qhov kev ntsuam xyuas los yog kev khiav hauj lwm txoj hauj lwm (kho tshuab thiab hluav taws xob interlocking).
c. Thaum lub trolley nyob rau hauv qhov kev xeem los yog kev khiav hauj lwm txoj hauj lwm thiab tsis muaj kev tswj voltage, lub Circuit Court breaker yuav tsis raug kaw thiab tsuas yog qhib manually (hluav taws xob interlocking).
d. Thaum lub trolley nyob rau hauv txoj haujlwm ua haujlwm, cov kab hluav taws xob tswj tau raug kaw thiab tsis tuaj yeem rub tawm.
e. Kev hloov hauv av tsuas tuaj yeem raug kaw thaum lub trolley nyob rau hauv qhov kev sim / kev cais tawm lossis tshem tawm (txhim kho kev sib cuam tshuam).
f. Thaum lub ntiaj teb hloov mus kaw, lub trolley tsis tuaj yeem txav los ntawm qhov kev sim / kev cais tawm mus rau txoj haujlwm ua haujlwm (txhim kho kev sib tshuam).
g. Cov khoom siv sib txuas ntxiv, xws li ntsuas lub ntsuas hluav taws xob, tuaj yeem ntsia tau rau ntawm lub trolley thiab / lossis lub ntiaj teb hloov kev ua haujlwm mechanism.
Txhawb kev txawj ntse customization:
a. Wireless ntsuas ntsuas ntsuas ntsuas ntsuas nrog tus kheej tsim lub zog tuaj yeem ntxiv, uas muaj kev nyab xeeb thiab tsis muaj kev saib xyuas;
b. Cov yam ntxwv ntawm kev soj ntsuam kev daws teeb meem, kev saib xyuas lub sijhawm tiag tiag ntawm cov ntaub ntawv kev ua haujlwm ntawm Circuit Court breaker, kev tshawb pom ntxov thiab kev daws teeb meem thaum ntxov ntawm kev phom sij zais;
C. Hluav taws xob txee nkag mus rau hauv kev daws teeb meem, kev ua haujlwm nyob deb kom paub meej txog kev nyab xeeb ntawm tus kheej;
D. Lub chaw ua haujlwm tshawb nrhiav tuaj yeem tshawb xyuas qhov kev laus ntawm cov khoom qub hauv lub sijhawm.
Cov khoom siv
KYN28-24 Cov Khoom Siv Hluav Taws Xob Hluav Taws Xob Sab Hauv Tsev yog siv rau cov chaw tsim hluav taws xob,Cov khoom lag luam (tshuaj, hlau, roj av, thee, thiab lwm yam), cov kab hluav taws xob hluav taws xob,Lub zog infrastructure.
Product Outline Drawing

Daim duab 1. Qhov Loj ntawm KYN28-24 nruab nrab txee 800

Daim duab 2. Dimensions ntawm KYN28-24 nruab nrab txee 1000
Cim npe nrov: kyn28-24 sab hauv tsev armored hlau-kab hloov khoom siv, Tuam Tshoj kyn28-24 sab hauv tsev armored hlau-pob hloov khoom manufacturers, lwm tus neeg, Hoobkas