Tiv tauj Box rau KYN 28-24
video
Tiv tauj Box rau KYN 28-24

Tiv tauj Box rau KYN 28-24

1. Rated voltage: 24kV
2. Txoj kev txhim kho: Vertically ntsia rau tom qab ntawm lub txee, txuas nrog thiab sib dhos nrog cov thawj busbar.
3. Compatible Txee: Haum rau KYN28A-24 hom txee.
4. Cov Khoom Zoo: Kev tiv thaiv Circuit Court, kev faib hluav taws xob, hluav taws xob tsis zoo, kev tiv thaiv hluav taws xob, thiab kev hloov pauv ib puag ncig.
Xa kev nug
Khoom Taw qhia

Lub thawv tiv tauj rau KYN28-24 yog ib qho tseem ceeb ntawm cov khoom siv hluav taws xob, ua haujlwm rau lub hom phiaj ntawm kev rwb thaiv tsev, kev sib cais, thiab kev hloov pauv. Tshwj xeeb tshaj yog, kev tsim ntawm lub thawv tiv thaiv kom muaj kev rwb thaiv tsev zoo ntawm cov high voltage thawj lub ntsiab hluav taws xob hluav taws xob thiab cov khoom siv hauv av, nrog rau ntawm theem, yog li ua kom muaj kev nyab xeeb ntawm lub voj voog. Tsis tas li ntawd, lub thawv tiv tauj muab kev ua haujlwm xws li rwb thaiv tsev thaiv kev tiv thaiv, tiv tauj busbar kev txhawb nqa, thiab kev sib cais sib cais, uas tuaj yeem ua ke lossis teeb tsa sib cais raws li kev tsim qauv thiab kev ua haujlwm ib puag ncig.

 

Khoom Specifications

Specification Sheet

Tsis muaj.

Yam khoom

Chav tsev

Hnub tim

1

Rated Voltage

kV ua 24
2

Rated Tam sim no

A

630/1250/1600/2000/2500/3150

3

Fais fab zaus Withstand Voltage

kV / min

65

4

Ib nrab Tso Cai Limit Tus Nqi

pc ua

Tsawg dua los yog sib npaug li 5

5

Khoom siv

 

Epoxy cob

Khoom zoo

 

Kev tiv thaiv Circuit Court

Lub thawv tiv tauj tuaj yeem sib cais tam sim no kom tsis txhob muaj kev sib tsoo xws li hluav taws xob thiab hluav taws xob luv luv, ua kom muaj kev nyab xeeb ntawm lub voj voog.

01

Fais fab faib

Lub thawv tiv tauj tuaj yeem faib hluav taws xob zoo rau ntau yam khoom siv hluav taws xob, ua kom zoo rau kev siv hluav taws xob.

02

High Voltage Resistance

Lub thawv tiv tauj feem ntau muaj qhov siab voltage kam rau ua, ua los tswj cov hluav taws xob siab tam sim no, kom ntseeg tau qhov kev ua haujlwm ntawm lub voj voog.

03

Kev tiv thaiv rwb thaiv tsev

Cov insulators nyob rau hauv lub thawv tiv tauj tuaj yeem cais cov tam sim no zoo, tiv thaiv cov teeb meem xws li xau thiab arcing, yog li tiv thaiv Circuit Court thiab khoom siv.

04

Environmental Adaptability

Lub thawv tiv tauj feem ntau yog tsim los tiv thaiv ntau qhov chaw ua haujlwm, nrog rau cov yam ntxwv xws li dej tsis zoo, plua plav pov thawj, thiab tiv thaiv corrosion.

05

Cov khoom siv

 

Lub thawv hu rau KYN28-24 yog dav siv nyob rau hauv ntau yam high voltage circuits, tshwj xeeb tshaj yog nyob rau hauv kev sib kis, substations, thiab industrial thiab mining lag luam.

 
01
 

kis tau tus mob systems

Hauv kev sib kis kab ke, lub thawv hluav taws xob tiv thaiv hluav taws xob yog siv los txuas cov kab sib txuas thiab cov chaw sib txuas, ua lub luag haujlwm tseem ceeb hauv kev sib txuas cable thiab kev tiv thaiv.

 
02
 

substation systems

Hauv substation systems, nws txuas cov khoom siv hauv substation thiab cables, ua kom yooj yim rau kev faib thiab txais hluav taws xob.

 
03
 

industrial thiab mining enterprises

Hauv kev lag luam thiab kev lag luam mining, lub siab hluav taws xob tiv tauj lub thawv txuas cov tshuab hluav taws xob thiab cov khoom siv hluav taws xob, kom ntseeg tau tias kev ua haujlwm zoo ntawm lub voj voog.

substations
 
Product Outline Drawing
 

Contact Box for KYN28-24 manufacturer

630A-1250ATiv tauj Box 

Contact Box for KYN28-24 factory

 

1600A-2000Ib lub thawv tiv tauj 

Contact Box for KYN28-24 supplier

2500A-3150ATiv tauj Box 

 

 

 

Qauv

Code

Code Loj (mm)

CHA01-24

A

49X140

B

M12

C

45

CHA02-24

A

54x120

B

M20

C

50

 

 

 

Cim npe nrov: hu rau lub thawv rau kyn 28-24, Tuam Tshoj hu rau lub thawv rau kyn 28-24 manufacturers, lwm tus neeg, Hoobkas

(0/10)

clearall