Cov khoom
12kV Insulator 1
2. Txoj Kev Txhim Kho: Vertically lossis horizontally mounted hauv lub txee thiab nruab nrab ntawm cov khoom siv hluav taws xob.
3. Compatible Cabinet: Tau tshaj KYN28A, XGN switchgear, thiab lwm yam.
4. Cov Khoom Zoo: Kev ua haujlwm zoo rwb thaiv tsev, kev ua haujlwm siab voltage, tsis tshua muaj dielectric poob, kev ua haujlwm ruaj khov, corrosion kuj, thiab kev ua haujlwm zoo los tiv thaiv kev ua qias tuaj.
12kV insulator yog ib qho tseem ceeb uas siv los cais cov conductors ntawm qhov sib txawv los yog nruab nrab ntawm cov conductors thiab cov khoom hauv av. Nws yog tsim los tiv taus voltage thiab mechanical stress. Cov thawj hom muaj xws li post insulators thiab composite insulators.
Khoom Specifications
|
Tsis muaj. |
Yam khoom |
Chav tsev |
Hnub tim |
| 1 |
Rated Voltage |
kV ua |
12 |
| 2 |
Kev ua haujlwm ib puag ncig |
-40 degree -40 degree |
|
| 3 |
Fais fab zaus Nrog Voltage |
kV / min |
48 |
| 4 |
Ib nrab Tso Cai Limit Tus Nqi |
pc ua |
Tsawg dua los yog sib npaug li 5 |
| 5 |
Khoom siv |
Epoxy cob |
Khoom zoo
12kV insulator muaj ntau yam zoo:
Zoo rwb thaiv tsev
Ua kom muaj txiaj ntsig zoo cais cov neeg siv hluav taws xob nrog cov peev txheej sib txawv, tiv thaiv kev xau tam sim no thiab luv luv Circuit Court, ua kom muaj kev nyab xeeb ntawm koj lub tshuab hluav taws xob.
High Voltage Endurance
Muaj peev xwm tiv taus siab dua voltage, ua kom muaj ntau yam rau ntau yam kev xa hluav taws xob thiab kev xav tau kev faib tawm.
Tsawg Dielectric Loss
Nws tuaj yeem txo lub zog poob, pab txhawb kev ua haujlwm tag nrho.
Kev ua haujlwm ruaj khov
Nyob ruaj khov nyob rau hauv ntau yam ib puag ncig, tiv thaiv deformation thiab tawg.
Corrosion Resistance
Nws muaj qee qhov kam rau cov tshuaj xws li acids, alkalis, thiab ntsev, thiab tsis yooj yim corroded.
Cov yam ntxwv tiv thaiv kev ua qias tuaj
Nws du nto resists av tsub zuj zuj, tswj nws cov khoom rwb thaiv tsev txawm nyob rau hauv ib puag ncig muaj kuab paug.
Cov khoom siv
Substations
Hauv substations, post insulators yog siv los txhawb cov khoom siv hluav taws xob xws li busbars, kev sib cais hloov, thiab cov khoom siv hluav taws xob los xyuas kom muaj kev nyab xeeb ntawm cov khoom siv.
Overhead Kab
Siv los txhawb cov khoom siv nyiaj siv ua haujlwm kom muaj kev tiv thaiv txaus los ntawm qhov chaw hauv av xws li ncej thiab yees.
Fais fab nroj tsuag
Hauv cov chaw tsim hluav taws xob, cov khoom siv hluav taws xob tom qab siv rau ntawm qhov hluav taws xob ntawm cov tshuab hluav taws xob, cov khoom siv hluav taws xob, thiab lwm yam khoom siv los muab cov rwb thaiv tsev thiab kev txhawb nqa.

Product Outline Drawing


|
Qauv |
M1 |
M2 |
M3 |
Qhov nrug deb (mm) |
|
CG101-12A |
M16 |
|
M16 |
|
|
CG101-12B |
M10 |
2-M8 |
M16 |
28 |
|
CG101-12C |
M12 |
2-M8 |
M16 |
28 |
|
CG101-12D |
M10 |
2-M10 |
M16 |
40 |
Cim npe nrov: 12kv insulator, Tuam Tshoj 12kv insulator manufacturers, lwm tus neeg, Hoobkas