Cov khoom
Tsau tiv tauj rau lub tshuab nqus tsev Circuit Court Breaker
2.Cov khoom siv hluav taws xob zoo
3. Kev ntseeg siab tiv tauj
4. Muaj zog abrasion tsis kam
5.Kev rwb thaiv tsev zoo
6.Adaptability rau ib puag ncig.
Cov kev sib txuas ruaj khov rau lub tshuab nqus tsev vacuum feem ntau yog hais txog lub voj voog nyob rau hauv ib qho chaw ruaj khov, tsis yog nrog lub voj voog rau thiab tawm haujlwm thiab kev txav ntawm cov khoom sib txuas, feem ntau yog siv ua ke nrog cov kev sib cuag dynamic, kom ua tiav kev sib txuas thiab kev sib txuas ntawm lub voj voog. . Piv txwv li, nyob rau hauv high-voltage switchgear, qhov kev sib cuag taag yog ib feem ntawm lub installation, thaum lub movable tiv tauj thiab taag tiv tauj, lub Circuit Court conductive; txav tau kev sib cuag deb ntawm qhov kev sib cuag ruaj khov, lub Circuit Court raug txiav.
Khoom Specifications
|
Tsis muaj. |
Yam khoom |
Chav tsev |
Hnub tim |
| 1 |
Rated Voltage |
kV ua |
12/24/40.5 |
| 2 |
Rated Tam sim no |
A |
630/1250/1600/2000/2500/3150/4000 |
| 3 |
Khoom siv |
|
Tooj T2 |
| 4 |
Kev kho saum npoo |
|
Nyiaj-plated |
Khoom zoo
Muaj peev xwm ua tau tam sim no ruaj khov, tsis txhob muaj teeb meem xws li kev tsim hluav taws xob thiab lub zog poob vim muaj kev tiv thaiv ntau dhau.
Kaw thiab txhim khu kev qha kev sib cuag nrog cov khoom txav tau yooj yim, nws tsis yooj yim rau kev sib cuag tsis zoo, xoob thiab lwm yam tshwm sim nyob rau hauv cov txheej txheem ntawm kev siv mus sij hawm ntev los xyuas kom meej qhov kev ua haujlwm ntawm lub voj voog.
Raws li kev sib txhuam tshwm sim nrog kev txav mus los thaum lub sijhawm qhib thiab kaw, nws yog ib qho tsim nyog yuav tsum muaj qee qhov kev puas tsuaj los tiv thaiv kev sib cuag thiab kev pab cuam lub neej tom qab siv mus ntev.
Ntxiv nrog rau cov khoom siv hluav taws xob, lwm qhov chaw ntawm qhov kev sib cuag zoo li qub yuav tsum muaj cov khoom siv rwb thaiv tsev zoo los tiv thaiv kev xau tam sim no thiab kev ua haujlwm luv luv.
tuaj yeem ua haujlwm ib txwm nyob rau hauv ib puag ncig sib txawv (xws li kub, av noo, plua plav, thiab lwm yam), nrog rau qee qhov kev tiv thaiv corrosion thiab oxidation.

Cov khoom siv
High-voltage switchgear: Nyob rau hauv high-voltage fais fab system, tsau hu rau lub tshuab nqus tsev Circuit Court breaker nyob rau hauv high-voltage switchgear yog siv los txuas thiab disconnect high-voltage circuits. Piv txwv li, nyob rau hauv 10kV, 35kV thiab lwm yam high-voltage switchgear, static contacts yog siv nyob rau hauv ua ke nrog movable hu kom paub txog kev tswj thiab kev tiv thaiv ntawm lub hwj chim kab.
Product Outline Drawing






Cim npe nrov: Tuam Tshoj taag tiv tauj rau lub tshuab nqus tsev Circuit Court breaker, Tuam Tshoj taag tiv tauj rau lub tshuab nqus tsev Circuit Court breaker manufacturers, lwm tus neeg, Hoobkas