Cov khoom
12 kV Bushing Insulator
2. Txoj Kev Txhim Kho: Nkag mus rau hauv cov txee lossis nruab nrab ntawm lub txee thiab lwm yam khoom siv hauv av.
3. Compatible Cabinets: Tau tshaj KYN28A-12 switchgear.
4. Cov Khoom Zoo: Kev ua haujlwm zoo ntawm hluav taws xob rwb thaiv tsev, kev tiv thaiv kev tiv thaiv, kev sib khi zoo dua, thiab kev teeb tsa yooj yim.
12kV bushing insulator yog tsim rau peb-theem AC tshuab fais fab chaw nres tsheb thiab cov khoom siv hluav taws xob substation nrog cov ntsuas hluav taws xob ntawm 12kV thiab zaus ntawm 50 ~ 60Hz. Nws yog siv los tso cai rau cov khoom siv hluav taws xob kom dhau los ntawm kev faib tawm, phab ntsa, lossis lwm yam khoom siv hauv av, thiab ua haujlwm raws li kev txhawb nqa rwb thaiv tsev thiab kev sib txuas ruaj khov ntawm cov khoom siv sab nraud (busbars).
Khoom Specifications
Specification Sheet
|
Tsis muaj. |
Yam khoom |
Chav tsev |
Hnub tim |
|
1 |
Rated Voltage |
kV ua |
12 |
|
2 |
Rated Tam sim no |
A |
630/1250/1600/2000/2500/3150/4000 |
|
3 |
Fais fab zaus Withstand Voltage |
kV / min |
48 |
|
4 |
Ib nrab Tso Cai Limit Tus Nqi |
pc ua |
Tsawg dua los yog sib npaug li 5 |
|
5 |
Khoom siv |
Epoxy cob |
Khoom zoo
12kV bushing insulator muaj ntau yam zoo:
Kev ua tau zoo ntawm hluav taws xob rwb thaiv tsev
Ua tau zoo tiv thaiv kev sib cuag ntawm cov khoom siv hluav taws xob ntawm qhov sib txawv, tsis txhob cuam tshuam hluav taws xob xws li luv-circuit. Nws tuaj yeem tiv taus cov qib voltage tshwj xeeb, ua kom muaj kev nyab xeeb thiab ruaj khov ua haujlwm ntawm lub zog hluav taws xob.
Mechanical Protection
Tiv thaiv cov xov hlau lossis cables hla cov phab ntsa los ntawm kev puas tsuaj xws li compression lossis kev sib txhuam ntawm phab ntsa. Nws kuj tseem pab tiv thaiv kev cuam tshuam sab nraud thiab kev vibrations los ntawm kev puas tsuaj rau cov xov hlau sab hauv.
Superior Sealing Performance
Tiv thaiv plua plav, ya raws, thiab lwm yam kab mob los ntawm kev nkag mus rau hauv lub bushing, uas yuav cuam tshuam rau nws cov hluav taws xob ua haujlwm. Kev sib khi zoo kuj tseem pab tiv thaiv cov tsiaj me los ntawm kev nkag mus, txo qhov kev pheej hmoo ntawm hluav taws xob.
Yooj yim Installation
Cov qauv yog qhov yooj yim, ua rau cov txheej txheem installation yooj yim, txuag lub sijhawm thiab nqi zog. Nws tuaj yeem hloov mus rau qhov sib txawv ntawm qhov chaw sib txawv thiab cov qauv phab ntsa.
Cov khoom siv
Cov phab ntsa plooj (porcelain) bushing yog siv rau hauv cov khoom siv hluav taws xob faib hluav taws xob thiab cov khoom siv hluav taws xob siab hauv cov chaw nres tsheb fais fab thiab cov chaw nres tsheb. Nws tso cai rau cov neeg ua haujlwm hla dhau los ntawm cov khoom siv hauv av, cov phab ntsa, lossis cov khoom siv hluav taws xob, txhawb cov khoom siv hluav taws xob kom insulate lawv hauv av lossis casing.
Product Outline Drawing
TGA01-12Hom
|
Qauv |
A |
B |
|
TGA01-1 |
53 |
10 |
|
TGA01-2 |
63 |
10 |
|
TGA01-3 |
65 |
15 |
|
TGA01-4 |
70 |
18 |
|
TGA01-5 |
85 |
15 |
|
TGA01-6 |
90 |
18 |


TGA02-12Hom
|
Qauv |
A |
B |
Qauv |
A |
B |
|
TGA02-1 |
65 |
15 |
TGA02-9 |
96 |
26 |
|
TGA02-2 |
70 |
18 |
TGA02-10 |
110 |
20 |
|
TGA02-3 |
70 |
45 |
TGA02-11 |
110 |
25 |
|
TGA02-4 |
85 |
15 |
TGA02-12 |
110 |
45 |
|
TGA02-5 |
90 |
20 |
TGA02-13 |
133 |
18 |
|
TGA02-6 |
90 |
25 |
TGA02-14 |
135 |
45 |
|
TGA02-7 |
90 |
45 |
TGA02-15 |
137 |
20 |
|
TGA02-8 |
90 |
70 |
TGA03-12Hom
|
Qauv |
A |
B |
Qauv |
A |
B |
|
TGA03-1 |
70 |
18 |
TGA03-8 |
110 |
45 |
|
TGA03-2 |
85 |
15 |
TGA03-9 |
110 |
70 |
|
TGA03-3 |
90 |
18 |
TGA03-10 |
133 |
18 |
|
TGA03-4 |
90 |
20 |
TGA03-11 |
135 |
45 |
|
TGA03-5 |
90 |
22 |
TGA03-12 |
133 |
68 |
|
TGA03-6 |
90 |
45 |
TGA03-13 |
137 |
20 |
|
TGA03-7 |
110 |
18 |
TGA03-14 |
137 |
65 |

Cim npe nrov: 12kv bushing insulator, Tuam Tshoj 12kv bushing insulator manufacturers, lwm tus neeg, Hoobkas