JN15-12 Sab Hauv Tsev Grounding Hloov
video
JN15-12 Sab Hauv Tsev Grounding Hloov

JN15-12 Sab Hauv Tsev Grounding Hloov

1. Rated voltage: 12kV
2. Txoj Kev Txhim Kho: Center-mounted handcart lossis taag txee.
3. Compatible Txee: KYN28-12 series switchgear, tshwj xeeb uas tsim cov khoom ruaj khov.
4. Cov khoom ua raws li cov qauv: GB / T 1985, GB / T 11022, IEC 60129.
5. Nws yog siv rau hauv cov khoom siv hluav taws xob hauv av.
Xa kev nug
Khoom Taw qhia

JN15-12 sab hauv av hloov pauv yog cov khoom lag luam siab heev uas tsim los ntawm cov thev naus laus zis tshiab hauv kev hloov pauv hauv av hauv tsev thiab thoob ntiaj teb. Tom qab kev sim ua tiav, nws qhov kev ua tau zoo ua raws li cov qauv ntawm GB / T1985 ("AC High-Voltage Disconnectors thiab Earthing Switches") thiab IEC 129, ua rau nws haum rau AC lub zog ntawm 12kV thiab hauv qab no. Nws tuaj yeem siv nrog ntau yam qauv high-voltage switchgear rau kev tiv thaiv hauv av.

 

Khoom Specifications

Tsis muaj.

Lub npe

Chav tsev

Cov ntaub ntawv

1

Rated Voltage

kV ua

12

2

Rated Zaus

Hz

50/60

3

Rated Short-Time Withstand Current

kA

31.5/40

4

RatedWtivCurrent (Peak)

kA

80

5

RatedDuration ntawmShort-Circuit ua

s

4

6

Rated Power Frequency Withstand Voltage

kV ua

42

7

RatedLightnhauvImpulseWtivVoltage

kV ua

75

8

Neeg kho tshuabEkev ua siab ntev

Sijhawm

5000

9

Tom Qab Qhib Kev Sib Txuas Sib Txuas

mm

Ntau dua lossis sib npaug rau 125

Khoom zoo
 

JN 15-12 sab hauv tsev hloov av muaj ntau yam zoo:

Compact loj, sib haum nrog ntau theem sib nrug.

Yooj yim thiab compact qauv, lub teeb yuag.

Kev ua haujlwm yooj yim, yooj yim installation.

Zoo thermal stability, muaj peev xwm ua haujlwm ruaj khov rau 4 vib nas this.

Kaw thiab qhib ceev yog ywj siab ntawm kev tuav haujlwm.

Standard configuration yog phau ntawv ua haujlwm; ib qho kev xaiv hluav taws xob ua haujlwm kuj muaj.

Cov khoom siv

 

JN15-12 hloov hauv av hauv tsev yog siv hauv cov khoom siv hluav taws xob hauv av los tiv thaiv cov neeg ua haujlwm thaum kho.

 
Product Outline Drawing

 

JN15-12 Indoor Grounding Switch manufacturer

 

Lus ceeb toom:

1. Yog hais tias qhov kev ncua deb ntawm theem yog 150 hli, nws yog ib qhov tsim nyog yuav tsum tau nce lub insulated partition ntawm theem;

2. The width of fixed contact is 40mm when the distance between phases is ≤180mm; the width of fixed contact is 60mm when the distance between phases is >180mm;

3. Qhov hloov hauv av muab cov khoom tso tawm hauv ob qho kev qhia; lub ntsiab ncej txuas mus rau sab laug rau sab laug ua haujlwm, thiab txuas mus rau sab xis rau txoj haujlwm txoj cai.

 

Secondary Wiring Diagram
 

 

1. Nyob rau hauv ib txwm muaj, qhov hloov hauv av muab ob pawg sib txuas rau ob qho tib si kaw thiab qhib txoj haujlwm;

2. Kev hloov hluav taws xob hauv av yog ua raws li qhov kev xav tau tshwj xeeb.

 

 

 

Cim npe nrov: jn15-12 sab hauv tsev grounding hloov, Tuam Tshoj jn15-12 sab hauv tsev grounding hloov manufacturers, lwm tus neeg, Hoobkas

(0/10)

clearall