24kv Tus thawv tiv thaiv

24kv Tus thawv tiv thaiv

1. Rated Voltage: 24Kv
2. Rated tam sim no: 630/1200/2000/2500 / 3150A
3. Tshaj tawm txee: Haum rau Kyn28a-24 hom khoom.
4. Khoom Muag Zoo: Kev ntseeg siab thiab kev ntseeg tau, kev tiv thaiv kev nyab xeeb kev nyab xeeb ib puag ncig kev nyab xeeb ib puag ncig ib puag ncig, tsim kev nyab xeeb} ywj pheej.
Xa kev nug
Khoom Taw qhia

24kV Lub thawv sib cuag yog lub hauv paus insulating yog ib qho kev sib xyaw insulating los ntawm epoxy cob apg molal moulding txheej txheem. Nws yog tsuas yog siv nyob rau hauv trolley - hom hloov chaw thiab ua haujlwm ntawm cov haujlwm hluav taws xob thiab kev sib cais kev sib cais.

24kV contact box supplier

 

Cov Khoom Qhia Khoom Khoom

 

Kev qhia tshwj xeeb Stus mauj

S.N

Yam

Xov xwm

1

Cov Ntsuas Hluav Taws Xob

24KV

2

Rated tam sim no

630/1250/1600/2000/2500/3150A

3

Zaus withsttorage voltage

42KV / 5min

4

Laug xob laim ua nrog voltage

75kv peak nqi (tiv tauj rau hauv av)

5

Kev Tso Tawm Ib nrab

Tsawg dua los yog sib luag rau 5pC (1.1xun)

6

Kev ntsuas ntsuas kub

Ntev - kev ua haujlwm xaus qhov kev kub siab ntau dua lossis sib npaug nrog 65k (hauv kab nrog GB / T 11022 tus qauv)

7

Dab tsi yog khoov zog

Ntau dua los yog sib npaug rau 150mpa (epoxy resin cov khoom)

8

Rwb Cevhij Kuj

Ntau dua los yog sib npaug rau 109Ω (Li qub), loj dua los yog sib npaug rau 108Ω (Tom qab ntub)

9

Creepage nrug deb

Ntau dua los yog sib npaug rau 300mm (hom qauv), ntau dua lossis sib npaug nrog 400mm (txhim kho)

10

Lub zog tensile

Ntau dua los yog sib npaug rau 80MPA (kev sib cuag sib txuas)

11

Kev khiav hauj lwm kub

-10 Degree ~ {{{{+40℃(ib txwm), - 25℃~ {{degree (tsawg degree)

12

Tus txheeb ze cov av noo

Tsawg dua los yog sib npaug rau 95% (tsis muaj hws ntawm 20 degree)

13

qho siab

Tsawg dua los yog sib npaug rau 1000m (li qub), 2000M (toj hom xaiv)

14

Kev Nyab Xeeb Qib

Ⅲ Qib (Rwb thaiv tsev tsim yuav tsum tau dag zog)

15

Kev Tiv Thaiv Qib

Ip4x

16

Daim Ntawv Pov Thawj

GB / T 11022 (Kev Xav Tau Kev Xav Tau Rau Siab-} voltage switchgear)

DL / T 404 (Cov txheej txheem kev ua haujlwm rau kev txiav txim sab hauv tsev siab siab - voltage switchgear)

IEC 62271 -} 200 (General Specification rau High-Voltage Switchgear)

 

Cov tau txais daim ntawv thov

 
 

24kV Lub thawv tiv thaiv tau siv rau high- voltage switchgear SystemE nrog lub ntsuas hluav taws xob ntawm 2430a rau 4000a.

Cov khoom kom zoo dua

 
Koj puas paub tus 24kv Tus Hu Xov Tooj Zoo?
 

High rwb thaiv tsev thiab ntseeg tau

Zoo rau ib puag ncig kev yoog raws

Kev Nyab Xeeb Kev Nyab Xeeb

Txij Nkawm - ywj pheej tsim

Kev Pab Cuam Tshuam

 

Khoom Siv Khoom

 

24kV lub thawv ntawv muaj ntau cov ntawv thov:

 

Lub Hwj Chim Tshuab

 

 

Muaj Kev Lag Luam

 

 

TSEV LOJ

 

 

Khoom qauv

 

 

 

 

Khoom qauv

 

 

24kV contact box

 

Tuam txhab ua hauj lwm

 

 

Cov Chaw Ua Lag Luam Tshwj Xeeb:Cov Chaw Tsim Khoom Tshwj Xeeb 12KV ~ 40.5Kv Internal thiab sab nraum zoov Kev Ua Haujlwm Crarcuit Court thiab sab nraum zoov Circuit Courmer thiab Switchgear thiab SF6 roj insulated Switchgear.

Pab Pawg:Muaj pab pawg kws tswj kev tshaj lij nrog ntau dua 20 xyoo ua haujlwm

Khoom:Muaj 6 patents, cov khoom tseem ceeb yog cov ntse thiab miniaturization hloov xws li VTZ, ZN85 thiab kev nyab xeeb kev lag luam thiab ua kom muaj kev nyab xeeb kev lag luam tsim khoom lag luam.

Pab pawg neeg thiab kev sib koom tes: Muaj ib pab neeg tshaj lij, muaj cov kws tshaj lij thiab cov tsev kawm ntawv, kev kawm thiab tshawb fawb.

TXwm qhuas:1. Kev ua haujlwm siab thiab tshiab thev naus laus zis

2. Memeber of Tuam Tshoj Cov Khoom Siv Hluav Taws Xob Kev Tsim Hluav Taws Xob

3. ISO9001 Kev Tswj Xyuas Kev Tswj Xyuas Zoo

4. Hom kev ntsuam xyuas ntawm Tuam Tshoj lub lab)

 

Cim npe nrov: 24kV Lub thawv tiv thaiv, Tuam Tshoj 24kv Hu rau lub thawv tuam txhab tuam txhab, cov chaw muag khoom, Hoobkas

(0/10)

clearall