12kV sensor yog tsim rau peb-theem AC tshuab fais fab chaw nres tsheb thiab cov khoom siv hluav taws xob substation nrog cov ntsuas hluav taws xob ntawm 12kV thiab zaus ntawm 50 ~ 60Hz. Nws yog siv los tso cai rau cov khoom siv hluav taws xob kom dhau los ntawm kev faib tawm, phab ntsa, lossis lwm yam khoom siv hauv av, muab kev txhawb nqa rwb thaiv tsev thiab tsim kom muaj kev ruaj ntseg nrog cov khoom siv sab nraud (busbars).
Khoom Specifications
|
Tsis muaj. |
Yam khoom |
Chav tsev |
Hnub tim |
| 1 |
Rated Voltage |
kV ua |
12 |
| 2 |
Rated Tam sim no |
A |
630/1250/1600/2000/2500/3150/4000 |
| 3 |
Fais fab zaus Withstand Voltage |
kV / min |
48 |
| 4 |
Ib nrab Tso Cai Limit Tus Nqi |
pc ua |
Tsawg dua los yog sib npaug li 5 |
| 5 |
Khoom siv |
Epoxy cob |
Khoom zoo
Muab kev soj ntsuam tas li ntawm cov insulators, txheeb xyuas cov teeb meem tshwm sim thaum ntxov. Nws taug qab qhov tsis xws li qhov ntsuas kub ntawm qhov ntsuas kub thiab cov dej ntws tawm tam sim no, tshaj tawm cov lus ceeb toom rau txhua qhov kev hloov pauv txawv txav, ua kom muaj kev tiv thaiv sai.
Muab cov kev ntsuas meej ntawm ntau yam tsis muaj. Optical sensors ntes cov kab nrib pleb thiab kev puas tsuaj, thaum lub ntsuas hluav taws xob ntsuas qhov hluav taws xob tam sim no los ntsuas kev ua haujlwm rwb thaiv tsev. Multi-sensor fusion technology txhim kho qhov tseeb thiab kev ntseeg tau.
Pab saib xyuas yam tsis tau kov lub insulator, tiv thaiv kev puas tsuaj. Qhov no yog tshwj xeeb tshaj yog pab tau rau high-voltage kis tau tus mob kab, qhov twg kev soj ntsuam yuav ua tau yam tsis muaj cuam tshuam lub hwj chim txaus.
Ua ke nrog kev sib txuas lus thev naus laus zis kom tso cai saib xyuas lub sijhawm tiag tiag los ntawm lub chaw tswj hwm. Qhov no txhim kho kev ua haujlwm, txo kev ua haujlwm, thiab txuag lub sijhawm.
Cov txheej txheem sau cov ntaub ntawv los ntsuas thiab kwv yees cov xwm txheej insulator. Cov ntaub ntawv keeb kwm yog siv los kwv yees lub neej ntev thiab qhov ua tsis tiav, pab hauv kev saib xyuas thiab hloov kev npaj.

Cov khoom siv
Siv dav hauv cov tshuab hluav taws xob, suav nrog cov kab hluav taws xob sib kis tau zoo thiab cov chaw nres tsheb, 12kV sensor txhim kho qhov kev ntseeg tau thiab kev nyab xeeb los ntawm kev saib xyuas cov txheej txheem insulator tsis tu ncua, txo qhov kev pheej hmoo ntawm kev tawg vim qhov tsis ua haujlwm insulator.
Product Outline Drawing
|
Qauv |
L |
A |
B |
Qhov deb |
|
CG 105-1 |
170 |
M10 |
M8 |
28 |
|
CG 105-2 |
170 |
M12 |
M8 |
28 |
|
CG 105-3 |
170 |
M16 |
M16 |
- |
|
CG 105-4 |
170 |
- |
M10 |
36 |
|
CG 105-5 |
175 |
M12 |
M8 |
28 |

|
Qauv |
L |
A |
B |
C |
Qhov deb |
|
CG 107-1 |
140 |
M8 |
M10 |
M16 |
28 |
|
CG 107-2 |
140 |
M8 |
M12 |
M16 |
28 |
|
CG 107-3 |
145 |
M8 |
M10 |
M16 |
28 |
|
CG 107-4 |
145 |
M8 |
M12 |
M16 |
28 |
|
CG 107-5 |
150 |
- |
M16 |
M16 |
- |
|
CG 107-6 |
150 |
- |
M16 |
M20 |
- |


Cim npe nrov: 12kv sensor, Tuam Tshoj 12kv sensor manufacturers, lwm tus neeg, Hoobkas