Cov khoom
12kV Embedded Ncej
2. Compatible handcart: 12kV sab hauv lub tshuab nqus tsev Circuit Court breakers thiab tshwj xeeb handcart.
3. Compatible Cabinet: Tau tshaj KYN28-12, XGN-12, thiab lwm yam.
4. Cov Khoom Zoo: muaj kev ntseeg siab, txhim khu kev tiv thaiv lub zog, thiab kev tiv thaiv ib puag ncig.
12kV embedded ncej yog ib qho kev ywj pheej tivthaiv qhov twg 12kV lub tshuab nqus tsev cuam tshuam thiab cov khoom siv hluav taws xob yog encapsulated nrog cov khoom siv rwb thaiv tsev. Nws cov txiaj ntsig tseem ceeb suav nrog cov qauv yooj yim, ob peb qhov tshem tau, muaj kev ntseeg siab, thiab muaj peev xwm rwb thaiv tsev zoo heev. Lub embedded ncej yog tsim los ntawm solidifying lub nqus interrupter thiab conductive terminals rau hauv ib chav tsev siv cov txheej txheem APG thiab epoxy resin.
Khoom Specifications
Daim ntawv Specification
|
Tsis muaj. |
Lub npe |
Chav tsev |
Cov ntaub ntawv |
Voltage Parameters
|
1 |
Rated Zaus (fr) |
Hz |
50/60 |
|
2 |
Rated Voltage (Ur) |
kV ua |
12 |
|
3 |
Rated Short-Time(1 min) Lub Hwj Chim Zaus Nrog Voltage (Ud) |
kV ua |
48 |
|
4 |
Rated Lightning Impulse Withstand Voltage (Peak) (Tshaj) |
kV ua |
75 |
Tam sim no Parameters
|
1 |
Rated tam sim no (Ir) |
A |
630/1250/1600/2000/2500/3150/4000/5000 |
|
2 |
Rated Short-Circuit Breaking Current (Isc) |
kA |
25/31.5/40/50 |
|
3 |
Kev khiav hauj lwm Cycles ntawm Rated Short-Circuit Breaking Current |
Lub voj voog |
30 |
|
4 |
Rated Short-Time Withstand Current (Ik) |
kA |
25/31.5/40/50 |
|
5 |
Rated Duration ntawm Short-Circuit (tk) |
s |
4 |
|
6 |
Rated Withstand Tam sim no (Peak) (Ip) |
kA |
63/80/100/125 |
|
7 |
Rated Short-Circuit Making Current (IMC) |
kA |
63/80/100/125 |
|
8 |
Rated Short-Circuit Breaking Current DC Component |
% |
40 |
|
9 |
Standard kev khiav hauj lwm ib ntus |
mm |
O-0.3s-CO-180s-CO O-180s-CO-180s-CO ( Ntau dua lossis sib npaug li 40kA) |
Mechanical Parameters
|
1 |
Mass of Moving Parts |
kg |
0.5~5 |
|
2 |
Self-Closing Force ntawm kev sib cuag |
N |
70±25~240±80 |
|
3 |
Rated Tiv tauj Siab |
N |
2000±200~6000±500 |
Yuav tsum muaj rau Hloov Mechanical Yam ntxwv
|
1 |
Clearance ntawm Moved thiab Fixed Contact |
mm |
9±1 |
|
2 |
Qhov Nruab Nrab Qhib Ceev (los ntawm 75% ntawm qhov sib chwv sib cuag mus rau qhov chaw kaw) |
m/s |
1.2±0.2 |
|
3 |
Nruab Nrab Kaw Ceev (los ntawm 30% ntawm qhov sib chwv sib cuag mus rau qhov chaw kaw) |
m/s |
0.7±0.2 |
|
4 |
Hu rau Kaw Bounce Sijhawm |
ms |
Tsawg dua los yog sib npaug 2 |
|
5 |
Kaw thiab qhib Tsis-Simultaneity ntawm kev sib cuag |
ms |
Tsawg dua los yog sib npaug 2 |
|
6 |
Hu rau Qhib Rebound Amplitude |
mm |
Tsawg dua los yog sib npaug 2 |
Kev ua neej nyob
|
1 |
Lub Sijhawm Cia |
Xyoo |
20 |
|
2 |
Mechanical Endurance |
Sijhawm |
10000 |
|
3 |
Tso cai hnav Thickness ntawm kev sib cuag |
mm |
3 |
Khoom zoo
Cov khoom siv
12kV embedded ncej yog tshwj xeeb tshaj yog haum rau lub hwj chim, machinery, tshuaj, metallurgy, mining, thiab lwm yam sectors ua hauj lwm nyob rau hauv tag nrho cov ua hauj lwm tej yam kev mob, nrog ib tug ntsuas voltage ntawm 12kV thiab ib tug zaus ntawm 50Hz / 60Hz.
Product Outline Drawing

630A-1600A

2000A

2500A-3150A

4000A-5000A
Cim npe nrov: Tuam Tshoj 12kv embedded ncej manufacturers, lwm tus neeg, Hoobkas
-
MNS Tsawg Voltage rho tawm Switchgearsaib ntxiv> -
24kV Embedded Ncejsaib ntxiv> -
ZN85-40.5 Miniaturized Nqus Circuit Court Breakersaib ntxiv> -
40.5kV Embedded Ncejsaib ntxiv> -
KYN28-24 Cov Khoom Siv Hluav Taws Xob Hluav Taws Xob Sab ...saib ntxiv> -
40.5kV Nqus Interrupter rau Nqus Circuit Court Breakersaib ntxiv>