GCS Tsawg Voltage rho tawm Switchgear
video
GCS Tsawg Voltage rho tawm Switchgear

GCS Tsawg Voltage rho tawm Switchgear

Cov Khoom Piav Qhia GCS tsis tshua muaj hluav taws xob rho tawm switchgear yog tsim rau cov chaw tsim hluav taws xob, kev lag luam petrochemical, metallurgy, textile, high-rise tsev fais fab mov thiab lwm yam lag luam. Nws yog siv nyob rau hauv loj fais fab nroj tsuag, petrochemical kev lag luam thiab lwm qhov chaw nrog high degree ntawm automation ...
Xa kev nug
Khoom Taw qhia
 
Khoom Description

 

GCSlow voltage rho tawmswitchgear yog tsim rau cov chaw tsim hluav taws xob, kev lag luam petrochemical, metallurgy, textile, high-rise tsev fais fab mov thiab lwm yam lag luam. Nws yog siv nyob rau hauv loj fais fab nroj tsuag, petrochemical kev lag luam thiab lwm qhov chaw nrog high degree ntawm automation thiab yuav tsum tau rau lub computer interface, raws li kev faib ntawm lub hwj chim nyob rau hauv peb-theem AC zaus 50Hz (60Hz), rated ua hauj lwm voltage 380V (660V), rated tam sim no 4000A thiab cov khoom siv hluav taws xob hauv qab no thiab cov khoom siv hluav taws xob, Nws yog cov khoom siv hluav taws xob tsis tshua muaj hluav taws xob ua tiav rau kev tswj hwm ntawm lub tshuab hluav taws xob, kev txwv tam sim no ntawm reactor thiab reactive zog them nyiaj.

 

 

Cov xwm txheej ntawm kev siv

 

 

 

 

 Tej yam kev mob ntawm kev siv

  • Cov huab cua puag ncig tsis tshaj +40 degree, tsis poob qis dua -5 degree, thiab qhov nruab nrab kub tshaj li 24- teev lub sij hawm tsis siab tshaj +35 degree ;
  • Atmospheric tej yam kev mob: Cov huab cua huv si thiab qhov txheeb ze av noo tsis tshaj 50% ntawm qhov kub siab tshaj ntawm +40 degree . Nyob rau ntawm qhov kub thiab txias dua cov av noo yog tso cai, piv txwv li 90% ntawm +20 degree , tab sis condensation vim kub hloov tau tso cai;

  • Qhov siab tsis tshaj 2000 meters saum toj no hiav txwv theem.

Cov xwm txheej tshwj xeeb ntawm kev siv

  • Yog tias qee cov khoom siv hluav taws xob siv hauv cov cuab yeej tsis tuaj yeem ua tau raws li cov kev ua haujlwm saum toj no, lub Hoobkas thiab cov neeg siv los sib tham txog kev daws teeb meem;

  • Thaum cov xwm txheej ntawm kev siv cov cuab yeej sib txawv ntawm cov kev siv ib txwm siv, tus neeg siv yuav sib tham nrog peb lub Hoobkas los daws qhov teeb meem.

 
Kev ua tau zoo thiab cov yam ntxwv

 

Tsis muaj.

Lub npe

Chav tsev

Cov ntaub ntawv

1

Main Circuit Court ntsuas voltage

V

AC380 (660)

2

Pab txhawb Circuit Rated Voltage

AC

220,380

DC

110,220

3

Rated zaus

Hz

50(60)

4

Rated rwb thaiv tsev voltage

V

660(1000)

5

ntsuas tam sim no

A

Kab rov tav busbar Tsawg dua lossis sib npaug rau 4000, ntsug busbar Tsawg dua lossis sib npaug rau 1000

6

Rated luv-lub sij hawm tiv taus tam sim no ntawm busbar

kA/1s

50,80,

7

Busbar ntsuas peak tiv taus tam sim no

kA/1s

105,175

8

Industrial zaus kuaj voltage

v/1 min

Lub ntsiab Circuit Court 2500, Pab pawg 1760

 Cov yam ntxwv ntawm tus qauv

  • Lub ntsiab ncej yog ua los ntawm 8MF qhib-kawg steel profiles, txias-tsim los ntawm 2.5mm txias phaj, nrog mounting qhov ntawm Φ9.2mm nrog modules ntawm 40mm, 20mm thiab 100mm ntawm ob sab ntawm cov profiles.
  • Lub ntsiab ncej yog ob hom, tag nrho modular thiab ib nrab (sab thav duab thiab kab teeb) welded.

  • Cov cuab yeej multifunctional chav yog sib cais nruj me ntsis, thiab nws cov compartments feem ntau yog muab faib mus rau hauv chav tsev ua haujlwm, chav tsheb npav, chav cable, thiab lub luag hauj lwm ntawm txhua chav tsev yog ib qho kev ywj pheej.

  • Kab rov tav busbars tau teem caij tiaj tus tom qab lub thav duab los ua kom qhov kev tiv thaiv ntawm cov busbars mus rau lub zog hluav taws xob tsim los ntawm kev khoov luv luv-circuit tam sim no.

  • Cov kab sib nrug yog nce thiab nqis hauv thiab tawm.

  • Ib lub tub rau khoom rau ib chav ua haujlwm.

  • Cov tub rau khoom tau muab faib ua plaub qhov loj: ib nrab chav tsev, ib chav tsev, ob chav, thiab peb chav nyob, nrog rau qhov ntsuas tam sim no ntawm 400A lossis tsawg dua.

  • Qhov ntev ntawm drawers hloov nyob rau hauv qhov siab, tab sis tsis nyob rau hauv dav los yog qhov tob, thiab cov tub rau khoom ntawm lub functional units yog interchangeable.

  • Txhua sab ntawm chav tsev muaj peev xwm txhim kho 11 ib chav tsev tub rau khoom lossis 22 chav tsev ib nrab tub rau khoom.

  • Cov tub rau khoom inlet thiab qhov hluav taws xob xaim siv cov xov tooj sib txawv ntawm cov khoom sib txawv ntawm cov qauv ntawm cov khoom sib txuas raws li qhov loj me tam sim no.

  • Lub 1/2 chav tsev tub rau khoom rau cable compartment adapter siv cov txheej txheem rov qab vaj huam sib luag hom adapter.

  • Kev sib txuas ntawm chav tsev tub rau khoom thiab cov khoom siv cable yog tsim los ntawm kev siv bar-hom adapters ntawm ntau qhov sib txawv raws li cov chav kawm tam sim no, lossis los ntawm kev tawm hauv qab.

  • Chav tsev drawers raug cim kom meej nrog txoj haujlwm ntawm kev sib cais, kaw, sim thiab tshem tawm.

  • Chav tsev tub rau khoom yog nruab nrog cov cuab yeej sib cuam tshuam.

 

Cov khoom siv
 
 

GGD AC Tsawg Voltage Distribution Txee muaj ntau yam kev siv:

 

Cov nroj tsuag muaj zog

 
Substations
 
Factories
 

Distribution system

 
 
Product Outline Drawing
 


01

02

 

 

 

 

 

 

 

 

 

Cim npe nrov: Tuam Tshoj gcs tsawg voltage rho tawm switchgear manufacturers, lwm tus neeg, Hoobkas

(0/10)

clearall