Blog

Home/Blog/Paub meej

Vim li cas thiaj siv SF6 hauv substations?

                                                                          

Lub luag haujlwm tseem ceeb ntawm lub tshuab hluav taws xob yog hloov hluav taws xob, nrog rau kev mloog zoo thiab faib hluav taws xob, tswj cov dej ntws ntawm hluav taws xob thiab kho qhov hluav taws xob. Vim tias qhov hluav taws xob uas tsim los ntawm lub tshuab hluav taws xob yog qhov siab thiab qhov hluav taws xob siv los ntawm cov neeg siv yog qhov tsawg, lub tshuab hluav taws xob feem ntau tsis ncaj qha muab lub zog rau cov neeg siv. Lub tshuab hluav taws xob yuav tsum tau txo qis cov zis hluav taws xob ntawm lub tshuab hluav taws xob ua ntej nws tuaj yeem muab rau cov neeg siv.

Nws ruaj khov, tsis yog - lom thiab muaj cov nplaim taws tsawg, tag nrho cov uas ua rau nws haum rau ntau qhov chaw ua haujlwm thiab qib voltage hauv kev lag luam fais fab.

SF6 cov khoom siv hluav taws xob muaj lub voj voog txij nkawm ntev, yooj yim rau kev tswj hwm, thiab tuav me me hauv av thiab qhov chaw. Cov khoom siv hluav taws xob sib txuas ua ke ua ke nrog SF6 roj raws li qhov nruab nrab ntawm cov khoom siv hluav taws xob tuaj yeem suav nrog cov hluav taws xob hluav taws xob, cov khoom siv hluav taws xob, cov khoom siv hluav taws xob, cov hloov hluav taws xob, cov khoom siv hluav taws xob, cov busbars, hluav taws xob ntes thiab lwm yam khoom siv. Tsis tas li ntawd, qhov siab -voltage nyob qhov chaw raug kaw tag nrho hauv lub plhaub steel, tsis muaj kev pheej hmoo ntawm hluav taws xob poob siab, uas txhim kho kev nyab xeeb ntawm kev ua haujlwm. Nyob rau tib lub sijhawm, vim yog kev sib xyaw ua ke, kev cuam tshuam ntawm ib puag ncig sab nraud (xws li kev lag luam muaj kuab paug, qhov siab siab, Frost, xob quaj thiab daus huab cua) raug zam.

LW25-126 sab nraum zoov high voltage porcelain SF6 Circuit Court breaker yog txaus siab los ntawmShaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd. yog sab nraum zoov, peb -theem AC 50Hz cov khoom siv hluav taws xob siab. Nws yog feem ntau siv los tiv thaiv kev sib kis thiab kev faib kab thiab tuaj yeem siv los ua kev khi khi. Qhov no Circuit Court breaker nta peb -theem mounted ntawm ib lub thav duab, tsis muaj kev pab rau ib zaug -theem ua haujlwm.

​

LW25-126 sab nraum zoov high voltage porcelain SF6 Circuit Court breaker muaj ntau yam zoo:

1.Superior tawg peev xwm

Thaum cuam tshuam cov magnetizing tam sim no, lub overvoltage tsawg dua ob zaug ntawm kev khiav hauj lwm voltage. Tsis tas li ntawd, thaum cuam tshuam kev them nqi tam sim no, tsis muaj qhov rov ua dua - tawm tsam lossis rov - qhov hluav taws xob tshwm sim.

2. Txhim khu kev rwb thaiv tsev

Cov khoom ntawm SF6 roj nyob ruaj khov nyob rau lub sijhawm, tiv thaiv cov khoom siv hluav taws xob thiab cov khoom siv hluav taws xob los ntawm oxidation thiab ua kom ruaj khov kub ua haujlwm.

3.Cov khoom siv

LW25-126 sab nraum zoov high voltage porcelain SF6 Circuit Court breaker muaj ntau yam zoo:

Nws yog feem ntau siv los tiv thaiv kev sib kis thiab kev faib kab thiab tuaj yeem siv los ua kev khi khi.

lw25-126 outdoor high voltage procelain sf6 circuit breaker supplier

Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd.

Hu rau: Ms.Grace Liu (Director of Sales Department)

 

Tel: +86 917 3661109 Fax: +86 917 6739416

 

Txawb: +86 18091765882(WhatsApp/Wechat/skype)

 

Lub Vev Xaib: https://www.xdtzelectrical.com