Kev xaiv nruab nrab- cov khoom siv hluav taws xob hluav taws xob faib hluav taws xob nyob ntawm qhov ntsuas hluav taws xob thiab kev ua haujlwm: rau cov qauv siv (tsawg dua lossis sib npaug li 27 kV),Lub tshuab nqus tsev Circuit Court breakersyog qhov kev xaiv zoo tshaj plaws (vim lawv cov eco-kev phooj ywg thiab kev saib xyuas- dawb huv), hos SF6 Circuit Court breakers raug pom zoo rau siab - kev ua tau zoo lossis kev hloov pauv ntau zaus.
Nqus Circuit Court Breakers: Qhov Kev Xaiv Tseem Ceeb rau Kev Faib Fais Fab
Eco-tus phooj ywg:
Lawv tsis siv cov pa hauv tsev cog khoom, yog li zam qhov kev pheej hmoo ntawm ib puag ncig cuam tshuam nrog SF6 roj- xws li tsim cov tshuaj lom lossis corrosive uas tshwm sim los ntawm kev cuam tshuam ntawm cov pa nrog arcs thiab noo noo- thiab ua raws li cov xwm txheej ib puag ncig loj.
Tsim nyog rau cov pa hluav taws xob: Lawv ua tau zoo nyob rau hauv nruab nrab -voltage pa tis (piv txwv li, 27kV thiab hauv qab) thiab yog cov kev xaiv hauv kev lag luam xws li Tuam Tshoj, Nyiv, thiab Tebchaws Meskas.
Kev tu- dawb thiab ntse:
Lawv muab cov neeg kho tshuab thiab hluav taws xob ntev lifespans thiab integrate yooj yim nrog sensing ntsiab thiab tswj systems kom txawj ntse, automated ua hauj lwm.
Kev txwv:
Raws li kev ua haujlwm tshwj xeeb-xws li hloov tawm cov motors me me- muaj kev pheej hmoo ntawm arc restrike ua rau switching overvoltage; ntxiv kev tiv thaiv overvoltage yuav tsum tau thaum tsim nyog.
SF6 Circuit Breakers: Cov cuab yeej muaj zog rau siab -Spec thiab tshwj xeeb daim ntawv thov
Superior Breaking Performance:
Lawv muaj peev xwm tawg tau zoo, ua rau lawv haum rau siab - muaj peev xwm thiab nquag- cov xwm txheej ua haujlwm, tsis muaj kev pheej hmoo ntawm kev tawm tsam lossis kev kav tom qab tawg.
Zoo heev Overvoltage Suppression:
Lawv pom muaj tsawg heev hloov cov overvoltage theem (overvoltage factor hauv qab 2.5 zaug), yuav tsum tsis muaj lwm voltage- txwv li thaum hloov inductive loads xws li tsis muaj -load transformers.
High rwb thaiv tsev thiab sealing:
Lawv muaj cov rwb thaiv tsev siab heev thiab zoo heev cov qauv sealing, muaj cov pa roj carbon monoxide, thiab tso cai rau kev saib xyuas yooj yim.
Kev txwv:
Nyob rau hauv kev sib xyaw ua ke ntawm hluav taws xob arcs thiab noo noo, cov pa roj yuav tsim cov khoom muaj kuab lom lossis corrosive decomposition; Tsis tas li ntawd, hauv qee thaj tsam, nws qhov kev ua tau zoo ib puag ncig yog qis dua ntawm lub tshuab nqus tsev.
Kev pom zoo xaiv zaum kawg
Yog tias koj lub zog hluav taws xob yog 27 kV lossis qis dua thiab tsis tas yuav hloov pauv ntau zaus, lub tshuab nqus tsev vacuum yog qhov kev xaiv zoo dua; lawv cov phooj ywg ib puag ncig thiab kev saib xyuas-dawb xwm zoo sib xws nrog cov qauv kev faib hluav taws xob niaj hnub.
Yog hais tias lub kaw lus voltage tshaj 27 kV, los yog yog hais tias daim ntawv thov muaj siab heev - muaj peev xwm tawg, yuav tsum tau tshwj xeeb kev nyab xeeb, los yog xav tau heev heev ua hauj lwm,SF6 Circuit Court breakersraug pom zoo.
Thaum koj xav tauLTZ-40.5 Sab Hauv Tsev High Voltage SF6 Circuit Breaker, thov hu rau peb txhua lub sijhawm.

Txhim khu kev qha Vacuum Circuit Breakers, Customized rau cov neeg siv khoom thoob ntiaj teb
Kev cob qhia & Pab Pawg Muag Khoom|Nyob rau -Tsev xa tuaj
12KV / 24KV / 40.5KV lub tshuab nqus tsev Circuit Court breakers
Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd.
Peb qhov chaw nyob
No.1 East Gaoxin Avenue, High-tech Development Zone, Baoji City, Shaanxi Province, Suav teb
Xov tooj
+86 18091767067(WhatsApp/Wechat/Telegram)
E -mail