Covtawg peev xwmntawm lub Circuit Court breaker yog nws "lifeline" raws li ib tug tiv thaiv ntaus ntawv, ib tug parameter sib npaug zos rau qhov tseem ceeb raws li nws rated voltage.
Yog tias qhov ntsuas hluav taws xob txhais tau tias nws "theem ntawm kev ua haujlwm," ces lub peev xwm tawg txiav txim siab nws "kev ciaj sia los yog kev tuag."
Hauv qhov tseem ceeb: Ib lub tshuab hluav taws xob uas muaj peev xwm tawg tsis txaus yuav tsis tsuas yog ua tsis tiav qhov luv luv luv - qhov ua txhaum ntawm qhov hluav taws xob tab sis tuaj yeem tawg puas tsuaj, ua rau muaj kev puas tsuaj loj.
⚠️ Qhov cuam tshuam ncaj qha ntawm kev tawg tsis txaus
Thaum lub kaw lus hluav taws xob tau ntsib qhov luv luv tam sim no, qhov txhaum tam sim no tuaj yeem ncav cuag kaum tawm txhiab tus amperes, uas qhov chaw xav tau siab heev ntawm lub peev xwm tawg ntawm Circuit Court breaker. Yuav ua li cas yog tias lub peev xwm tawg ntawm Circuit Court breaker tsis txaus?
Tsis tuaj yeem tua cov arc: Cov hluav taws xob arc tsis tuaj yeem tua, ua rau hluav taws kub hauv lub Circuit Court breaker.
Nce siab nyob rau hauv lub Circuit Court breaker ua rau ib tug siab -kub hluav taws xob arc, ua rau cov huab cua nyob rau hauv lub Circuit Court breaker kom loj hlob.
Thaum kawg, lub Circuit Court breaker tuaj yeem tawg thiab tawg!
Kev tawg yuav rhuav tshem cov khoom uas nyob ib sab, yog li ua rau hluav taws!
🎯 Qhov tseem ceeb tshwj xeeb hauv cov phiaj xwm hluav taws xob tauj dua tshiab
Hauv cov cheeb tsam no -PV, cua, lub zog cia- xaiv qhov muaj peev xwm tawg yog qhov tseem ceeb tshwj xeeb:
| Daim ntawv thov Scenario | Vim Li Cas Kev Txhaum Cai yog qhov tseem ceeb | Yam Risk |
|---|---|---|
| Loj PV / Cua Farms | Cov kab sib txuas ntawm kab sib chaws yuav tsum tiv taus siab tam sim no los ntawm daim phiaj siv hluav taws xob. Cov kab sib sau thiab lub ntsiab transformer tseem xav tau kev tiv thaiv zoo. | Tsis muaj peev xwm txaus ntawm lub ntsiab substation breaker tuaj yeem ua rau nws puas tsuaj, tshem tawm tag nrho cov nroj tsuag ntawm kab sib chaws thiab nres tag nrho cov nyiaj tau los. |
| Battery Energy Storage Systems (BESS) | Cov roj teeb tuaj yeem tso tawm qhov txhaum tam sim no nrog qhov nrawm nrawm thiab qhov loj. DC tivthaiv thiab nce nrawm ua rau muaj kev sib tw hnyav, xav tau ultra- nrawm, siab - muaj peev xwm cuam tshuam. | Kev cuam tshuam tsis pub dhau milliseconds tuaj yeem ua rau thermal runaway hauv roj teeb hlwb, uas yuav ua rau lub pob tawg tag lossis tawg. |
| Diesel Generator Teeb | luv-circuit tam sim no ntawm lub tshuab hluav taws xob tso zis yog siab heev thiab decays maj mam, yuav tsum breakers nrog tshwj xeeb tiv taus thiab cuam tshuam lub zog. | Ib qho tsis ua haujlwm ntawm lub tshuab hluav taws xob tso tawm hluav taws xob tuaj yeem ua rau lub tshuab hluav taws xob nws tus kheej ua rau lub zog hluav taws xob puas tsuaj, uas tuaj yeem ua rau poob ntawm cov cuab yeej tseem ceeb. |
Kev muaj peev xwm tawg yog qhov tseem ceeb tshaj plaws thiab tsis yog -kev sib tham tsis tau ntawm lub Circuit Court breaker, ncaj qha txuas rau kev nyab xeeb ntawm tag nrho lub zog hluav taws xob. Hauv cov phiaj xwm hluav taws xob tauj dua tshiab, qhov twg cov khoom siv kim thiab kev ua haujlwm txuas ntxiv yog qhov tseem ceeb, nws qhov kev xaiv raug yog qhov tseem ceeb tshaj plaws.
Khoom Description

ZW32-12M Permanent Sib Nqus Nqus Circuit Court Breaker
1. Rated voltage: 12kV
2. Kev khiav hauj lwm Mechanism: Permanent magnetic operating mechanism.
3. Installation Method: Sab nraum zoov kev them nyiaj yug / ncej-mounted installation.
4. Cov khoom ua raws li cov qauv: GB/T1984-2014, GB/T11022-2011.
5. Cov Khoom Zoo: Cov qauv yooj yim, muaj kev ntseeg siab, kev pab lub neej ntev, kev tswj xyuas siab heev, kev ua haujlwm muaj zog, thiab lub zog ua haujlwm tsawg.
Tiv tauj peb

Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd
Hu rau: Melody Sun (Export Sales manager)
Email: xdtz03@westpowerelectric.com