Lub caij nplooj ntoos hlav kev khiav hauj lwm mechanism ntawm nruab nrab thiab siab voltage Circuit Court breakers yog ib tug dav siv txhua yam kev khiav hauj lwm mechanism. Nws lub hauv paus ntsiab lus tseem ceeb yog siv lub zog tso tawm los ntawm lub caij nplooj ntoos hlav ua ntej - khaws cia kom tsav lub Circuit Court breaker kom ua tiav cov haujlwm qhib thiab kaw. Cov hauv qab no yuav nthuav dav nws cov txheej txheem ua haujlwm, suav nrog kev saib xyuas cov txheej txheem, lub zog cia, kaw thiab qhib cov txheej txheem.
Core Structure thiab Energy Flow
Lub caij nplooj ntoos hlav mechanism feem ntau muaj cov hauv qab no cov khoom tseem ceeb:
1. Zog Cia System: Qhov no suav nrog lub zog cia lub cev muaj zog, txo qis zog, lub zog cia ratchet / cam, thiab kaw lub caij nplooj ntoos hlav.
2. Cov Khoom Siv Hluav Taws Xob Retention / Tso Tawm: Lub latch kaw (catch), uas yog siv los tswj lub caij nplooj ntoos hlav lub zog cia lub xeev thiab tso tawm thaum tau txais cov lus txib.
3. Transmission Linkage System: Hloov lub caij nplooj ntoos hlav lub zog rau hauv txoj kab tawm ntawm kev sib cuag.
4. Qhib Qhov System: Qhov no suav nrog lub caij nplooj ntoos hlav qhib (feem ntau tsis muaj zog, siv los ua kom lub qhov qhib), qhib lub latch, thiab qhib coil.
5. Tswj Cheebtsam: Kaw coil, qhib coil, auxiliary hloov, lub zog cia qhov taw qhia, thiab lwm yam.
Core zog flow:
Hluav taws xob lub zog (lub cev muaj zog) → Mechanical zog (lub caij nplooj ntoos hlav lub zog cia) → Tso tawm kom tsav lub zog ntawm kev sib cuag.
Cov txheej txheem khiav hauj lwm ntxaws
Theem Ib: Spring Energy Storage Process
Qhov no yog qhov yuav tsum tau ua ua ntej rau txhua txoj haujlwm. Lub caij nplooj ntoos hlav yuav tsum tau compressed thiab lub zog khaws cia ua ntej kaw qhov hloov.
1. Pib Lub Zog Cia
Thaum lub caij nplooj ntoos hlav tsis energized, lub zog cia raws li txoj cai qhia ntawm lub mechanism qhia "Tsis Energized".
Lub zog tswj hluav taws xob txuas lub zog rau lub zog cia lub cev muaj zog (uas tuaj yeem pib manually lossis txiav).
2. Zog Cia:
Lub cev muaj zog tsav lub zog cia lub ntsiab ncej kom tig los ntawm kev txo cov iav teeb.
Lub cam los yog eccentric log ntawm lub ntsiab ncej maj mam compresses lub caij nplooj ntoos hlav kaw (feem ntau yog lub caij nplooj ntoos hlav loj loj lossis lub caij nplooj ntoos hlav torsion), ua rau nws deform thiab khaws cov khoom siv hluav taws xob ntau.
3. Kev Tiv Thaiv Lub Zog Cia:
Thaum lub caij nplooj ntoos hlav compressed mus rau qhov siab tshaj plaws (lub zog cia ua tiav), lub kaw latch (catch) tau txais los ntawm lub caij nplooj ntoos hlav quab yuam, xauv lub ntsiab ncej kom tsis txhob tig rov qab.
Lub zog cia cov xwm txheej qhia tau hloov mus rau "Energized", thiab lub koom haum hloov pauv yog ua kom txiav tawm lub cev muaj zog, nres lub cev muaj zog.
Nyob rau ntawm lub sijhawm no, lub Circuit Court breaker yog npaj kom tau txais cov lus txib kaw txhua lub sijhawm.
Theem Ob: Kaw Cov Txheej Txheem Ua Haujlwm
Tom qab kaw cov lus txib raug muab tso tawm, lub tshuab tso tawm lub zog lub caij nplooj ntoos hlav khaws cia kom thawb cov neeg sib txuas tseem ceeb ntawm lub Circuit Court breaker kom kaw.

1. Kaw cov lus txib ua:
Lub teeb liab kaw yog xa mus rau thaj chaw deb lossis hauv zos, ua kom lub zog kaw lub kauj (los yog tuav lub khawm kaw).
Cov tub ntxhais ntawm lub kauj txav txav, tawm tsam lossis rub lub latch kaw (catch), tso tawm.
2. Lub zog tso tawm thiab kis tau tus mob:
Tom qab kaw lub latch raug tso tawm, lub xauv lub zog cia lub ntsiab ncej tig ntawm kev kub ceev nyob rau hauv qhov kev txiav txim ntawm lub caij nplooj ntoos hlav muaj zog kaw.
Kev sib hloov ntawm lub ntsiab ncej yog hloov dua siab tshiab rau hauv cov lus tsa suab ntawm lub Circuit Court breaker lub insulating rub qws los ntawm ib tug meej plaub -bar linkage (los yog cam-linkage mechanism) rau kev txav thiab quab yuam transformation.
3. Tiv tauj kaw:
Lub insulating rub qws tsav cov kev sib cuag nyob rau hauv lub Circuit Court breaker lub arc extinguishing chamber kom txav ceev ceev upwards (los yog kab rov tav) thiab ua kom ntseeg tau kev sib cuag nrog nyob ruaj ruaj, ua kom tiav cov kev twb kev txuas Circuit Court.
Thaum kawg ntawm qhov txheej txheem kaw, lub tshuab txiav ua ob qho tseem ceeb:
a. Re- txhawb nqa lub caij nplooj ntoos hlav qhib: Nyob rau theem kawg ntawm qhov kev txiav txim kaw, lub caij nplooj ntoos hlav qhib yog ncab lossis compressed los ntawm kev sib txuas los khaws lub zog rau qhov qhib tom ntej.
b. Re- energizing lub caij nplooj ntoos hlav kaw (optional, rau tsis siv neeg reclosing mechanisms): Qee qhov tsim pib lub cev muaj zog thaum kawg ntawm cov txheej txheem kaw kom tam sim ntawd pib lub zog tom ntej; lwm tus pib lub zog cia tom qab kaw tiav.
4. Kev saib xyuas lub xeev:
Tom qab kaw tiav lawm, qhov qhib latch xauv, ua kom lub Circuit Court breaker nyob rau hauv qhov chaw kaw.
Lub auxiliary hloov pauv lub xeev, txiav tawm lub kaw Circuit Court thiab npaj mus txuas rau lub qhib Circuit Court.
Kauj Ruam 3: Qhib Txheej Txheem Ua Haujlwm
Qhov qhib tsuas yog nyob ntawm lub zog khaws cia ntawm lub caij nplooj ntoos hlav qhib, thiab lub zog yuav tsum tau muaj tsawg dua li qhov kaw.
1. Qhib cov lus txib ua:
Cov cuab yeej tiv thaiv teeb meem teeb meem tsis pom kev lossis kev qhib phau ntawv tau ua, thiab qhib lub kauj yog energized.
Lub hauv paus ntawm qhov qhib coil txav, tawm tsam qhov qhib latch kom tso nws.
2. Ceev ceev:
Tom qab qhov qhib latch raug tso tawm, lub zog khaws cia hauv lub caij nplooj ntoos hlav qhib yog tam sim ntawd tso tawm.
Los ntawm txoj kev sib kis, nws tsav cov kev sib cuag kom txav mus sai sai (lossis nyob rau hauv qhov kev coj rov qab) thiab cais los ntawm kev sib cuag zoo li qub. Lub arc yog sai sai extinguished nyob rau hauv lub arc extinguishing chamber, thiab lub Circuit Court yog disconnected.
cov yam ntxwv tseem ceeb
1. Kev ywj pheej zog: Lub zog ua haujlwm yog los ntawm lub caij nplooj ntoos hlav thiab muaj kev ywj pheej ntawm tus nqi tam sim ntawm daim phiaj hluav taws xob, ua kom muaj kev ntseeg siab.
2. Clear "Kaw-Open" Ib ntus: Lub zog yuav tsum muab khaws cia ua ntej kaw; thaum lub sijhawm kaw lossis tom qab kaw, nws cia li khaws lub zog rau kev qhib.
3. Lub zog ua haujlwm siab: Lub caij nplooj ntoos hlav tuaj yeem khaws lub zog tseem ceeb, ua rau nws haum rau siab -voltage thiab ultra-siab-voltage circuit breakers uas xav tau lub zog loj.
4. Lub neej siv tshuab ntev: Cov khoom tseem ceeb muaj kev hnav zoo, thiab lub neej txhua yam feem ntau nyob ntawm ntau txhiab mus txog kaum txhiab lub voj voog.
5. Rov qab muaj peev xwm: Nws tuaj yeem ua qhov rov qab tsis siv neeg ceev ntawm "O-0.3s-CO" (tom qab qhib thawj zaug, lub caij nplooj ntoos hlav rov ua kom muaj zog hauv lub sijhawm luv luv kom ua tiav qhov kaw).
6. Kho kom pom tseeb: Caij nplooj ntoos hlav qaug zog cov yam ntxwv, hnav thiab precision ntawm lub xauv lub cuab yeej, thiab lubrication tej yam kev mob yog cov ntsiab lus tseem ceeb rau kev txij nkawm.
Lub voj voog ua haujlwm raws li daim duab kos duab
Lub xeev pib: Qhib txoj hauj lwm, lub caij nplooj ntoos hlav tsis muaj zog
↓ (Energizing motor pib)
Lub xeev A: Qhib txoj hauj lwm, lub caij nplooj ntoos hlav energized
↓ (Tau txais cov lus txib kaw)
Lub Xeev B: Cov txheej txheem kaw (Lub caij nplooj ntoos hlav tawm, tsav kaw, thiab ib txhij ua kom lub caij nplooj ntoos hlav qhib)
↓ (Kawm hauv qhov chaw)
Lub xeev C: kaw txoj hauj lwm, qhib lub caij nplooj ntoos hlav energized, kaw lub caij nplooj ntoos hlav yuav tsis energized
↓ (Tau txais cov lus txib qhib)
Lub Xeev D: Qhib txheej txheem (Qhib lub caij nplooj ntoos hlav tawm)
↓ (Qhib hauv qhov chaw)
Xeev E: Qhib txoj hauj lwm, kaw lub caij nplooj ntoos hlav tsis muaj zog (Rov qab mus rau thawj lub xeev lossis xeev A)
Hauv cov ntsiab lus
Nyob rau hauv cov ntsiab lus, lub caij nplooj ntoos hlav kev khiav hauj lwm mechanism ua tiav txhim khu kev qha, ceev thiab tsis siv neeg tswj ntawm Circuit Court breaker lub qhib thiab kaw kev khiav hauj lwm los ntawm cov neeg kho tshuab logic ntawm lub cev muaj zog ua ntej - khaws cia lub zog - latch tuav - electromagnetic triggering thiab tso tawm. Nws yog ib qho ntawm cov ntsiab lus tseem ceeb tshaj plaws thiab cov txheej txheem kev ua haujlwm classic rau niaj hnub nruab nrab thiab siab -voltage circuit breakers.
vS1-12 nqus Circuit Court breaker
VS1-12 nqus Circuit Court breakeryog ib qho khoom siv hloov hauv tsev nrog qhov ntsuas hluav taws xob ntawm 12kV thiab AC 50/60Hz. Nws txais ib qho kev sib koom ua ke ntawm kev ua haujlwm thiab tsim nyog rau ntau yam kev lag luam thiab kev lag luam mining, nrog rau cov khoom siv hluav taws xob. Nws tuaj yeem siv los ua ib lub tawb nqa khoom siv nrog KYN28A-12 switchgear, los yog raws li ib qho chaw ruaj khov nrog cov khoom siv sib cuam tshuam, ua rau nws haum rau XGN2 thiab lwm cov khoom ruaj khov.

tiv tauj peb
Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd.
Hu rau: Ms.Grace Liu (Director of Sales Department)
Email: xdtz04@westpowerelectric.com
Txawb: +86 18091765882(WhatsApp/facebook)
Lub Vev Xaib: https://www.xdtzelectrical.com
Ntxiv: Nanpo Zos, Chencang Avenue Jintai District Baoji City, Shaanxi Province, Suav.