Cov txheej txheem rwb thaiv tsev ntawm lub tshuab nqus tsev hluav taws xob feem ntau txiav txim siab lawv lub cev qhov ntev, qib voltage, thiab daim ntawv thov scenarios. Lub hom phiaj tseem ceeb ntawm kev tsim hluav taws xob sib txawv yog los xyuas kom ntseeg tau tias muaj zog dielectric nyob rau hauv thiab sab nraum lub Circuit Court breaker nyob rau hauv high voltage tej yam kev mob.
Cua- insulated Circuit Breaker
Qhov no yog cov feem ntau tsoos thiab structurally yooj yim daim ntawv.
Cov yam ntxwv ntawm tus qauv:
Tag nrho cov khoom siv nyob xws li lub tshuab nqus tsev cuam tshuam, cov khoom siv hluav taws xob, thiab cov khoom siv hluav taws xob txhawb nqa tau raug rau huab cua.
Rwb thaiv tsev ntawm theem thiab nruab nrab ntawm theem thiab hauv av (lub switchgear enclosure) yog nyob ntawm qhov sib txawv ntawm huab cua.
Yuav kom ua tiav qhov kev ncua deb txaus, nws qhov ntim feem ntau yog loj heev.
Txoj Cai Ua Haujlwm:
Kev rwb thaiv tsev tseem ceeb: Cia siab rau txoj kev dav dav txaus kom cais tawm siab -voltage nyob qhov chaw los ntawm qhov chaw hauv av.
Theem -rau-theem rwb thaiv tsev: Cia siab rau qhov sib txawv ntawm huab cua loj kom cais qhov chaw nyob ntawm ntau theem.
Qhov zoo thiab qhov tsis zoo:
Qhov zoo: Cov qauv tsim qauv, kev tsim khoom yooj yim, tus nqi qis, thiab yooj yim rau kev tshuaj xyuas thiab hloov khoom siv.
Qhov tsis zoo: Cov ntim loj: Vim tias qhov rwb thaiv tsev tsis tshua muaj zog ntawm huab cua (kwv yees li 3 kV / mm), yuav tsum muaj kev nyab xeeb loj. Ua rau muaj kev cuam tshuam rau ib puag ncig: noo noo (condensation), plua plav, tshuaj tsuag ntsev, tshuaj lom neeg ua paug, thiab kev nkag mus rau tsiaj me tuaj yeem txo nws cov rwb thaiv tsev ua haujlwm, ua rau muaj teeb meem tshwm sim. Yog li ntawd, cov cuab yeej pabcuam xws li lub tshuab cua sov thiab lub tshuab ua pa yuav tsum tau muab rau lub tshuab hloov pauv.
Common rwb thaiv tsev lub tog raj kheej nqus Circuit Court Breaker
Cov qauv no tau tsim los kov yeej qhov tsis txaus ntawm cov cua ntshiab rwb thaiv tsev thiab tam sim no yog cov thev naus laus zis tshaj plaws hauv nruab nrab-voltage field.
Cov yam ntxwv ntawm tus qauv:
Raws li kev rwb thaiv tsev huab cua, cov khoom siv rwb thaiv tsev, feem ntau yog silicone roj hmab lossis epoxy resin, ntxiv rau qhov tseem ceeb ntawm cov rwb thaiv tsev (xws li qhov txav thiab zoo li qub ntawm lub tshuab nqus tsev cuam tshuam).
Ib daim ntawv ntau yog lub tshuab nqus tsev cuam tshuam raug kaw hauv silicone roj hmab bushing nrog tiab.
Txoj Cai Ua Haujlwm:
Lub ntsiab rwb thaiv tsev: Sib koom los ntawm "cov khoom siv rwb thaiv tsev + cua". Cov ris tsho silicone roj hmab tsis tsuas yog muab kev nkag siab ntxiv ntawm qhov deb tab sis kuj tseem tiv thaiv kom txhob muaj pa phem vim lawv qhov dej tsis zoo.
Theem-rau-theem rwb thaiv tsev: Feem ntau tseem nyob ntawm huab cua, tab sis feem ntau insulating partitions yog ntxiv los txhim kho nws.
Qhov zoo:
Qhov tseem ceeb txhim kho cov pa phem flashover thiab noo noo tsis kam, nrog kev muaj zog ib puag ncig adaptability.
Yuav ua tau ntau dua compact dua huab cua-insulated Circuit Court breakers ntawm tib theem voltage.
Kev ruaj ntseg zoo dua, nrog cov khoom tseem ceeb tseem siv tau.
Qhov tsis zoo: Tus nqi siab dua li huab cua- insulated Circuit Court breakers, thiab tseem tsis zoo li cov khoom sib npaug li - kaw ncej- hom hluav taws xob hluav taws xob.

embedded ncej hom nqus Circuit Court breaker
Qhov no yog tam sim no tshaj plaws thiab compact daim ntawv.
Cov yam ntxwv ntawm tus qauv:
Lub tshuab nqus tsev cuam tshuam thiab nws cov txuas sab sauv thiab sab qis thiab lwm yam khoom siv hluav taws xob tseem ceeb yog kev sib xyaw ua ke hauv epoxy resin los ntawm cov txheej txheem tsis siv neeg siab gel los tsim cov khoom rwb thaiv tsev module - "ncej".
Txoj Cai Ua Haujlwm:
Lub ntsiab rwb thaiv tsev: Yuav luag tag nrho los ntawm epoxy resin. Epoxy resin muaj lub zog rwb thaiv tsev siab heev (txog 20 kV / mm), uas yog 6-7 npaug ntawm huab cua.
Theem-rau-theem rwb thaiv tsev: Vim lub ntsiab rwb thaiv tsev muaj zog muab los ntawm epoxy resin, qhov kev ncua deb ntawm theem tuaj yeem tsim me me, txo qhov loj tag nrho ntawm lub Circuit Court breaker.
Qhov zoo:
Compact heev: Qhov ntim tsawg tshaj plaws, ua rau nws haum rau qhov chaw - txwv tsis pub siv (xws li nkoj, mines, thiab lub thawv- hom substations).
Kev ntseeg siab: Ua tiav kaw, kom tsis txhob muaj kev cuam tshuam ib puag ncig (moisture, plua plav, tshuaj lom neeg), ua tiav "kev tu- dawb".
Kev nyab xeeb siab: Lub plhaub epoxy muab kev tiv thaiv zoo thiab ua rau nws nyuaj rau kov qhov chaw nyob.
Qhov tsis zoo:
Tus nqi tsim khoom siab tshaj plaws.
Thaum lub tshuab nqus tsev vacuum interrupter los yog rwb thaiv tsev cov khoom puas lawm, lawv tsis tuaj yeem kho nyias; tag nrho cov ncej yuav tsum tau hloov, uas ua rau cov nqi kho mob siab.
Summary and Selection
Cov keeb kwm kev loj hlob ntawm peb cov txheej txheem rwb thaiv tsev no qhia txog cov qauv ntawm lub tshuab nqus tsev vacuum breakers mus rau miniaturization, kev ntseeg siab, thiab kev saib xyuas - dawb.
Cov Cai Xaiv: Tus nqi thiab qhov chaw tsis hnov tsw: Cov huab cua ib txwm muaj -cov hluav taws xob thaiv hluav taws xob tuaj yeem txiav txim siab.
Ntsuas kev ua tau zoo, tus nqi thiab kev saib xyuas: Composite insulated Circuit Court breakers yog qhov kev xaiv zoo tshaj plaws thiab muaj txiaj ntsig tam sim no.
Qhov chaw txwv tsis pub dhau, ib puag ncig hnyav thiab qhov yuav tsum tau muaj kev ntseeg siab tshaj plaws: Cov khoom siv - kaw cov ncej Circuit Court breakers yuav tsum tau muab qhov tseem ceeb, txawm hais tias qhov kev nqis peev thawj zaug yog siab dua, qhov kev ntseeg tau zoo nyob rau hauv tag nrho lub neej voj voog yuav muaj txiaj ntsig dua.

pebVTZ Lub tshuab nqus tsev Circuit Court breaker
VTZ-12 nqus Circuit Court breakermuaj ntau yam zoo:VTZ-12 nqus Circuit Court breakeryog tsim los ntawm Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd. (tus qauv tshwj xeeb ntawm Tongzhong Hluav Taws Xob Co., Ltd.) yog ib qho hluav taws xob sab hauv tsev rau cov ntsuas hluav taws xob 12kV, AC 50/60Hz. Nws siv lub tshuab ua haujlwm modular thiab tsim nyog rau ntau yam kev lag luam thiab kev lag luam mining, nrog rau cov khoom siv hluav taws xob. Nws tuaj yeem siv los ua ib lub hnab nqa khoom siv rau kev siv nrogKYN28A-12 switchgear, los yog raws li ib qho chaw ruaj khov nrog cov khoom siv sib cuam tshuam, ua rau nws haum rau XGN2 thiab lwm cov khoom ruaj khov.
1.Peformance ntawm Circuit Court breaker:
E2-C2-M2
2. Kev saib xyuas yooj yim:
lub modular mechanism tsim tso cai rau kev hloov pauv yooj yim ntawm qhov kaw thiab qhib coils yam tsis tas yuav tsum tau dismantling lwm yam khoom. Qhov no tshem tawm qhov kev xav tau ntawm kev sim lossis kev hloov kho tom qab hloov pauv, ua kom cov neeg siv hloov lawv tus kheej, ua rau kev saib xyuas tom ntej yooj yim dua.
3.High conductivity kev ua tau zoo:
cov khoom muaj qhov zoo-tsim hluav taws xob hluav taws xob uas ua tau raws li 1.1 npaug ntawm qhov ntsuas kub tam sim no nce qib.
4.Wide daim ntawv thov ntau yam:
Cov khoom lag luam muaj ntau daim ntawv thov, ntsuas tam sim no ntawm 630A txog 5000A, thiab ntsuas qhov tawg tam sim no ntawm 20kA txog 50kA. Nws yog tsim rau txhua qhov chaw nyob hauv qhov siab ntawm 4500 meters thiab kev ua haujlwm kub ntawm -40℃txog 40 degree.
Txhawb kev txawj ntse customization:
ib. Nws tuaj yeem ntxiv qhov ntsuas kub ntsuas hluav taws xob wireless nrog tus kheej -tsim qauv tsim kom muaj kev nyab xeeb thiab txij nkawm- ua haujlwm dawb.
b. Nws muaj cov yam ntxwv ntawm kev soj ntsuam cov kev daws teeb meem los muab qhov tseeb - lub sijhawm saib xyuas cov ntaub ntawv siv hluav taws xob hluav taws xob rau kev tshawb pom ntxov thiab kev daws teeb meem ntawm cov teeb meem tshwm sim.
c. Nws muaj lub tshuab hluav taws xob nkag hauv lub txee kom tso cai rau cov chaw taws teeb ua haujlwm kom muaj kev nyab xeeb ntawm tus kheej.
d. Tiag -lub sij hawm tivthaiv kev laus tuaj yeem kuaj pom los ntawm kev kuaj tawm ib nrab.
tiv tauj peb
Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd.
Hu rau: Ms.Grace Liu (Director of Sales Department)
Email:xdtz04@westpowerelectric.com
Txawb: +86 18091765882(WhatsApp/Wechat/skype)