Lub tshuab hluav taws xob disconnecting yog ib qho khoom siv tseem ceeb uas tsis tseem ceeb hauv lub siab -voltage fais fab kev faib hluav taws xob. Nws lub hom phiaj tsim yog los muab qhov "pom pom, lub cev tsis sib haum xeeb" txhawm rau ua kom tiav kev sib cais ntawm lub voj voog ntawm lub hwj huam mov thaum tu lossis kho.
Kev piav qhia ntxaws txog cov haujlwm tseem ceeb
Isolating Power Supply (Safety Isolation)
Qhov no yog lub luag haujlwm tseem ceeb tshaj plaws ntawm kev hloov pauv. Qhov pom kev cuam tshuam qhov taw qhia muab cov neeg ua haujlwm nrog kev paub tseeb txog kev nyab xeeb, tiv thaiv kev sib tsoo hluav taws xob los ntawm kev siv dag zog yuam kev.
Hloov ua haujlwm (Hloov ua haujlwm hom)
Nyob rau hauv txoj kab hluav taws xob sib txuas, feem ntau yuav tsum tau kho cov khoom siv hluav taws xob, xws li hloov cov khoom thauj los ntawm ib lub npav mus rau lwm qhov, lossis muab lub zog rov qab rau hauv kev ua haujlwm. Tshem tawm cov keyboards, siv nrog rau kev sib txuas nrog cov hluav taws xob hluav taws xob, ua kom muaj kev hloov pauv hloov tau yooj yim, tab sis "so ua ntej kaw" cov txheej txheem kev sib txuas yuav tsum tau ua raws li nruj me ntsis.
Me me tam sim no Switching (Limited Capacity)
Thaum disconnect keyboards tsis tuaj yeem hloov cov khoom thauj loj, lawv tuaj yeem ua haujlwm ntawm cov tam sim no me me nyob rau hauv cov xwm txheej tshwj xeeb, xws li:
· Unloaded circuits ntawm voltage transformers thiab surge arresters.
· Unloaded transformers nrog excitation tam sim no tsis tshaj 2A.
· Unloaded kab nrog capacitive tam sim no tsis tshaj 5A.
(Ceeb Toom: Cov txiaj ntsig tshwj xeeb yuav tsum raug xa mus rau cov khoom siv lub npe thiab cov kev cai; cov kev xav tau sib txawv nyob ntawm qib voltage.)
Cov txheej txheem khiav hauj lwm (Cov txheej txheem nthuav dav)
Kev ua haujlwm ntawm kev sib txuas ntawm cov keyboards yuav tsum nruj me ntsis ua raws li "tsib kev tiv thaiv", tshwj xeeb tshaj yog tiv thaiv kev hloov pauv ntawm kev qhib lossis kaw hauv qab load.
1. Fais fab tuag ib ntus (ua ntej kho)
· Kauj Ruam 1: Disconnect lub Circuit Court breaker (txiav tawm lub load tam sim no).
· Kauj ruam 2: Qhib lub hwj chim - sab disconnect hloov.
Kauj Ruam 3: Ntsuas qhov hluav taws xob thiab txuas cov xaim hauv av (yog tias tsim nyog).
2. Fais fab- ntawm Kev Ua Haujlwm Ib ntus
• Kauj Ruam 1: Tshem cov xaim hauv av (yog tias tsim nyog).
• Kauj Ruam 2: Kaw lub hwj chim - sab disconnect hloov.
• Kauj Ruam 3: Kaw lub load- sab disconnect hloov.
• Kauj Ruam 4: Kaw lub Circuit Court breaker.
hauv luv
Nyob rau hauv luv luv, disconnecting keyboards yog "tus saib xyuas kev nyab xeeb" ntawm lub hwj chim system. Kev siv kom raug yuav tsum muaj kev paub txog txuj ci, kev paub txog txheej txheem, thiab tus cwj pwm nruj.
GW4-126 Sab nraum zoov High Voltage Isolating Hloov
GW4-126 Sab nraum zoov High Voltage Isolating Hloovyog ob -kab kab rov tav rotation. Nws suav nrog 3 tus ncej, txhua tus ncej yog ob npaug -kab qauv, feem ntau yog tsim los ntawm lub hauv paus thiab ib qho kev txhawb nqa insulator. Txhua tus ncej muaj 2 insulators, uas feem ntau ntsia rau ntawm cov kabmob rooj zaum ntawm ob qho kawg thiab txuas los ntawm tus ntoo khaub lig- txuas. Nws tuaj yeem tig kab rov tav hauv qhov ntau ntawm 90 degree. Lub conductive ib feem yog muab faib ua ob halves, uas yog raws li nyob rau hauv raws li nyob rau hauv lub insulator ncej, thiab kev sib cuag yog nyob rau hauv nruab nrab ntawm ob tug porcelain ncej. Thaum lub tshuab ua haujlwm, ib qho ntawm cov ncej insulators tig 90 degree, thiab lwm tus ncej insulating kuj tig 90℃tib lub sijhawm vim qhov txuas txuas txuas, thiab qhov hloov pauv tau qhib thiab kaw ntawm tib sab. Txhawm rau kom ntseeg tau tias qhov kev ua haujlwm raug raws theem ntawm lub disconnector thiab qhov hloov mus rau hauv av, txhim khu kev qha txhua yam thiab hluav taws xob cuam tshuam cov khoom siv thiab cov khoom siv.