Blog

Home/Blog/Paub meej

Dab tsi yog cov kev cai yooj yim rau lub tshuab nqus tsev vacuum Circuit Court breaker?

 

I. Txhim khu kev rwb thaiv tsev

 

Lub tshuab nqus tsev Circuit Court breakers yuav tsum tiv taus kev khiav hauj lwm voltages thiab ntau yam overvoltages (xws li hloov overvoltages thiab atmospheric overvoltages) thaum ua haujlwm. Lawv cov txheej txheem rwb thaiv tsev yuav tsum xyuas kom meej tias nws tsis tawg raws li cov xwm txheej no.

Cov kev cai tshwj xeeb muaj xws li:

 

Lub zog zaus tiv taus qhov hluav taws xob: Rau 12kV cov khoom, qhov inter-ncej thiab ncej- rau- hauv av tiv taus voltages yuav tsum yog 42kV, thiab inter- tawg tiv thaiv voltage yuav tsum yog 48kV.

 

xob laim impulse withstand voltage: Qhov inter-ncej thiab ncej- rau- av tiv taus voltages yuav tsum yog 75kV, thiab inter- tawg tiv thaiv voltage yuav tsum yog 84kV.

 

Txawm nyob rau hauv lub xeev qhib, lub tshuab nqus tsev interrupter so yuav tsum muaj txaus rwb thaiv tsev muaj peev xwm.

 

 

II. Zoo conductivity thiab thermal stability

 

Circuit Court breakers yuav tsum muaj peev xwm ua haujlwm ruaj khov thaum nqa cov ntsuas tam sim no rau lub sijhawm ntev thiab muaj peev xwm tshaj tawm.

 

Temperature Rise Control: Raws li qhov ntsuas tam sim no, qhov ntsuas kub ntawm txhua qhov yuav tsum tsis pub tshaj tus nqi teev.

 

Loop Resistance: DC tsis kam ntawm lub ntsiab Circuit Court yuav tsum tau raws li cov khoom specifications (xws li, Tsawg tshaj los yog sib npaug rau 60μΩ rau 12kV / 1250A cov khoom).

 

DC voltage poob txoj kev (tam sim no tsis pub tsawg tshaj 100A) yuav tsum tau siv los ntsuas qhov tsis kam ntawm cov khoom siv hluav taws xob.

 

 

III. Txaus siab rau txhua yam muaj zog

 

Lub zog cuam tshuam thaum lub sijhawm qhib thiab kaw

 

Electrodynamic quab yuam thaum cuam tshuam luv luv -circuit tam sim no

 

Ntau yam kev ntxhov siab sab hauv ntawm kev ua haujlwm mechanism

 

Muaj kev cuam tshuam los ntawm lwm lub zog xws li av qeeg

 

 

IV. Kev tawg thiab ua kom muaj peev xwm ua tau raws li qhov yuav tsum tau ua

 

Yuav tsum muaj peev xwm cuam tshuam qhov ntsuas luv luv -circuit tam sim no thiab muaj qee yam hluav taws xob lub neej (xws li, 20-50 tag nrho-muaj peev xwm cuam tshuam).

 

Yuav tsum tuaj yeem kaw qhov luv luv -circuit kaw tam sim no (tus nqi ncov).

 

Yuav tsum muaj peev xwm qhib thiab kaw cov capacitive tam sim no (piv txwv li, hloov lub txhab nyiaj capacitor) thiab cov inductors me me. Tshwj xeeb loads xws li tam sim no

 

 

V. Precise Mechanical Characteristic Parameters

 

 

Parameters Yam yuav tsum tau muaj (12kV)
Sib cuag nrug deb 8-12 hli
Tiv tauj Stroke 3-4 hli
Kaw Bounce Sijhawm Tsawg dua los yog sib npaug li 2ms
Asynchronous qhib thiab kaw Tsawg dua los yog sib npaug li 2ms
Nruab Nrab Kaw Ceev Kwv yees li . 0.6m/s
Nruab Nrab Qhib Ceev 0.95-1.2m/s

 

 

VI. Lub neej txaus

 

Mechanical Lifespan: Feem ntau yuav tsum tau ua haujlwm rau 10,000-30,000

 

Hluav taws xob Lifespan: Yuav tsum muaj tus naj npawb ntawm tag nrho - lub peev xwm luv luv - cuam tshuam tam sim no (xws li 20-50 zaug)

 

Nqus Lifespan: Lub sijhawm cia thiab tso cai hnav tuab ntawm lub tshuab nqus tsev cuam tshuam

 

 

VII. Environmental Adaptability

 

Qhov siab: Cov khoom lag luam tsim nyog rau Tsawg dua lossis sib npaug li 1000m, siab - qhov siab qhov khoom tuaj yeem ncav cuag 4600m

 

Ambient Kub: -25℃-+40 degree

 

Humidity: Txhua hnub nruab nrab cov av noo tsawg dua lossis sib npaug li 95%

 

Seismic Intensity: Tsis tshaj 8 degrees

 

 

VIII. Txhim khu kev khiav hauj lwm Mechanism

 

Txhim khu kev ua haujlwm thiab teb sai

 

Rwb thaiv tsev tsis kam ntawm qhov qhib thiab kaw coils yuav tsum tsis txhob tsawg dua 10MΩ

 

Smooth hluav taws xob thiab phau ntawv ua haujlwm yuav tsum yog ob qho tib si du

 

Kev cuam tshuam kev ua haujlwm xws li tiv thaiv-tswj thiab tiv thaiv- kev ua haujlwm tsis raug

 

Khoom Description

 

VTZ-12 1250Lub tshuab nqus tsev vacuumyog ib qho hluav taws xob sab hauv tsev rau cov ntsuas hluav taws xob 12kV, 1250A, AC 50 / 60Hz. Nws siv lub tshuab ua haujlwm modular thiab tsim nyog rau ntau yam kev lag luam thiab kev lag luam mining, nrog rau cov khoom siv hluav taws xob. Nws tuaj yeem siv los ua ib lub tawb nqa khoom siv nrog KYN28A-12 switchgear, los yog raws li ib qho chaw ruaj khov nrog cov khoom siv sib cuam tshuam, ua rau nws haum rau XGN2 thiab lwm cov khoom ruaj khov.

 