Kev xa khoom ntawm VS 1 12kV Nqus Circuit Court Breaker Ntawm XDTZ

 

VS1-12 lub tshuab nqus tsev vacuum breaker yog ib qho khoom siv sab hauv tsev nrog qhov ntsuas hluav taws xob ntawm 12kV thiab AC 50 / 60Hz.

Nws txais ib qho kev sib koom ua ke ntawm kev ua haujlwm thiab tsim nyog rau ntau yam kev lag luam thiab kev lag luam mining, nrog rau cov khoom siv hluav taws xob.

Nws tuaj yeem siv los ua ib lub tawb nqa khoom siv nrog KYN28A-12 switchgear, los yog raws li ib qho chaw ruaj khov nrog cov khoom siv sib cuam tshuam, ua rau nws haum rau XGN2 thiab lwm cov khoom ruaj khov.

VS1-12KV VACUUM CIRCUIT BREAKER SHIPPING

 

 

 

VS1-12kV VCB khoom ua ntej ntim

Ntau yam kev siv

 

VS1-12 cov khoom lag luam muaj ntau daim ntawv thov, ntsuas tam sim no los ntawm 630A txog 5000A, thiab ntsuas qhov tawg tam sim no ntawm 20kA txog 50kA. Nws yog tsim rau txhua qhov chaw nyob hauv qhov siab ntawm 4500 meters thiab kev ua haujlwm kub ntawm -40℃txog 40 degree.

 

vs1 12kv vcb shipping supplier

 
1. Rated voltage: 12kV
2. Kev khiav hauj lwm Mechanism: Integrated ncej kev khiav hauj lwm mechanism.
3. Txoj Kev Txhim Kho: Lub tsheb nqa nrog lub hauv paus kev ua haujlwm lossis lub txee ruaj khov.
4, Daim Ntawv Thov: Fais fab nroj tsuag, Industrial fields, Fais fab tuag systems, Fais fab infrastructures

vs1 12kv factory

 
5. Compatible Txee: Tau tshaj KYN28-12 series switchgear, XGN-12 tsau txee, HXGN-12 series nplhaib lub ntsiab units.
6. Cov Khoom Zoo: E2-C2-M2 kev ua tau zoo, kev ruaj ntseg thiab kev ntseeg siab, kev ua haujlwm zoo rwb thaiv tsev, thiab kev siv ntau yam.

 

 
 
VS1-12kV vCB tseem ceeb Accessories

 

spring operating mechanism of vs1 12kv vcb

01.

   

Lub caij nplooj ntoos hlav kev khiav hauj lwm mechanism ntawm VTZ Series yog lub cim tshiab kev khiav hauj lwm mechanism rau lub tshuab nqus tsev Circuit Court breakers tsim los ntawm XDTZ.

 

Nws tau tsim los tom qab kev nthuav dav thiab hauv - kev tshawb fawb tob hauv kev lag luam, kev sib koom ua ke nrog cov thev naus laus zis hauv tsev thiab kev paub dhau los.

 

 

02.

   

1.12kV theem kab kem vertically mounted ntawm 12kV nqus Circuit Court breaker ncej;


2.Kev txhim kho kev ua haujlwm ntawm hluav taws xob rwb thaiv tsev;


3.Txhim kho cov khoom siv tiv thaiv;


4. Yooj yim rau nruab thiab tswj.

vacuum interruptor of vs1 12kv

 

DETAIL DRAWING NTAWM VS1-12kV vCB

Professional R & D Pab Pawg

XDTZ Muab cov neeg siv khoom tshaj lij kev txhawb nqa.

3D Drawing

3D kos duab txhawb rau cov neeg siv khoom retrofitting tov thiab hloov qhov project.

VS1-12 DRAWING

VS1-12KV VCB DRAWING

Kev tsim kho tshiab

Innovation yog lub hauv paus ntawm peb txoj kev lag luam.

kev pabcuam

Peb tau cog lus tias yuav muab qhov tshwj xeeb tom qab- muag kev txhawb nqa rau peb cov neeg siv khoom thoob ntiaj teb.

 

Tiv tauj peb

 

 

Yuav koom tes nrog peb li cas?

Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltdtau tsim nyob rau hauv 2014 uas yog ib tug thawj coj innovator nyob rau hauv hluav taws xob kev lag luam nrog ntau tshaj 20 xyoo ntawm kev lag luam kev.

Peb qhov chaw nyob

Tsis yog. 1 East Gaoxin Avenue nyob rau hauv siab -Tech Development Zone ntawm Baoji City, Shaanxi Province, Suav teb

E -mail

xdtz03@westpowerelectric.com

vs1-12kv vcb xdtz China