Khoom taw qhia
VTZ-12 nqus Circuit Court breaker(tshwj xeeb qauv ntawm Tongzhong Electrical Co., Ltd.) yog tsim rau sab hauv tsev switchgear nrog ib tug nyob voltage ntawm 12kV, AC 50/60Hz. Nws siv lub tshuab ua haujlwm modular thiab tsim nyog rau ntau yam kev lag luam thiab kev lag luam mining, nrog rau cov khoom siv hluav taws xob. Nws tuaj yeem siv los ua ib lub tawb nqa khoom siv nrog KYN28A-12 switchgear, los yog raws li ib qho chaw ruaj khov nrog cov khoom siv sib cuam tshuam, ua rau nws haum rau XGN2 thiab lwm cov khoom ruaj khov.
1. Rated voltage: 12kV
2. Kev khiav hauj lwm Mechanism: Modular kev khiav hauj lwm mechanism.
3. Installation Method: Center-mounted handcart or fixed txee.
4. Compatible Txee: Tau tshaj KYN28-12 switchgear, XGN-12 tsau txee, HXGN-12 series nplhaib lub ntsiab units.
5. Cov khoom ua raws li cov qauv: GB/T1984-2014, GB/T11022-2011.
6. Cov Khoom Zoo: E2-C2-M2 kev ua tau zoo, kev saib xyuas yooj yim, kev ua haujlwm siab, kev siv ntau yam, thiab txhawb kev tsim kho ntse.
Thaum kawg, peb nug cov neeg siv khoom siv cov lus qhia, lawv tau hais rau peb tias qhov zoo yog qhov zoo.Tab sis lawv vam tias lawv tuaj yeem tau txais cov khoom lag luam ceev ceev ntawm kev xa khoom.
Khoom zoo
VTZ-12 nqus Circuit Court breakermuaj ntau yam zoo:
1. Kev ua haujlwm ntawm Circuit Court breaker: E2-C2-M2
2. Kev saib xyuas yooj yim: kev tsim qauv tsim qauv tso cai rau kev hloov pauv yooj yim ntawm qhov kaw thiab qhib coils yam tsis tas yuav tsum tau dismantling lwm yam khoom. Qhov no tshem tawm qhov kev xav tau ntawm kev sim lossis kev hloov kho tom qab hloov pauv, ua kom cov neeg siv hloov lawv tus kheej, ua rau kev saib xyuas tom ntej yooj yim dua.
3. High conductivity kev ua tau zoo: cov khoom nta ib tug zoo-tsim conductive circuit uas ua tau raws li 1.1 npaug ntawm qhov ntsuas kub tam sim no nce qib.
4. Daim ntawv thov dav dav: cov khoom lag luam muaj ntau daim ntawv thov dav, ntsuas tam sim no ntawm 630A txog 5000A, thiab ntsuas qhov tawg tam sim no ntawm 20kA txog 50kA. Nws yog tsim rau txhua qhov chaw nyob hauv qhov siab ntawm 4500 meters thiab kev ua haujlwm kub ntawm -40℃txog 40 degree.
5. Txhawb kev txawj ntse customization:
a. Nws tuaj yeem ntxiv qhov ntsuas kub ntsuas hluav taws xob wireless nrog tus kheej -tsim qauv tsim kom muaj kev nyab xeeb thiab txij nkawm- ua haujlwm dawb.
b. Nws muaj cov yam ntxwv ntawm kev soj ntsuam cov kev daws teeb meem los muab qhov tseeb - lub sijhawm saib xyuas cov ntaub ntawv siv hluav taws xob hluav taws xob rau kev tshawb pom ntxov thiab kev daws teeb meem ntawm cov teeb meem tshwm sim.
c. Nws muaj lub tshuab hluav taws xob nkag hauv lub txee kom tso cai rau cov chaw taws teeb ua haujlwm kom muaj kev nyab xeeb ntawm tus kheej.
d. Tiag -lub sij hawm tivthaiv kev laus tuaj yeem kuaj pom los ntawm kev kuaj tawm ib nrab.
Cov khoom siv
VTZ-12Lub tshuab nqus tsev Circuit Court breakermuaj ntau yam kev siv:
1. Cov nroj tsuag muaj zog
2. Kev lag luam (chemical kev lag luam, hlau, roj av, thee, thiab lwm yam)
3. Cov kab hluav taws xob hluav taws xob
4. Fais fab infrastructures

Thaum kawg, peb nug cov neeg siv khoom siv cov lus qhia, lawv tau hais rau peb tias qhov zoo yog qhov zoo.Tab sis lawv vam tias lawv tuaj yeem tau txais cov khoom lag luam ceev ceev ntawm kev xa khoom. Peb yuav ua peb lub nkoj zoo tshaj plaws
Yog tias koj txaus siab rau VTZ-12 seriesLub tshuab nqus tsev Circuit Court breaker, thov hu rau kuv txhua lub sijhawm. Peb tuaj yeem muab kev pabcuam OEM rau koj.
Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd.
Peb qhov chaw nyob
Nanpo Village, Chencang Avenue Jintai District Baoji City, Shaanxi Province, Suav.
Xov tooj
+86 18091767067(WhatsApp / Wechat)
E -mail