Cov hom hauv qab no yog tsim rau 12kV hu rau lub thawv.
CH1-10Q-150 (630-1250A) Lub cev muaj zog
CH2-10Q-180 (1250A) Cov khoom siv
CH3-10Q-190 (1600A) Lub cev muaj zog
CH4-10Q-208 (2000A) Lub cev muaj zog
CH5-10Q-250 (3150-4000A) Lub cev muaj zog
CH6-10Q-230 (3150-4000A) Lub cev muaj zog
1. Daim ntawv thov ntau yam
Muaj feem xyuam rau KYN28 hlau-clad switchgear ntawm rated voltage 12kV thiab rated zaus 50Hz.
2. Cov xwm txheej ntawm ib puag ncig kev pabcuam
- Qhov siab tshaj plaws ntawm huab cua nyob ib puag ncig yog +48℃; Qhov nruab nrab tus nqi ntawm cov txheeb ze txhua hnub yog los ntawm -25℃rau +35℃.
- Qhov siab tsis tshaj 1000m.
- Tus nqi nruab nrab ntawm cov av noo txhua hnub tsis tshaj 95%; Qhov nruab nrab tus nqi ntawm cov av noo txhua hli tsis tshaj 90%.
- Cov huab cua ib puag ncig tsis pom tseeb cuam tshuam los ntawm cov plua plav, pa taws, corrosive thiab / lossis cov pa roj, vapor lossis cov pa phem.
- Sab nrauv rwb thaiv tsev muaj kuab paug chav kawm: Ⅱ.
3. Technical parameters
- Lub teeb pom kev zoo tiv thaiv hluav taws xob: Ntau dua lossis sib npaug ntawm 75kV;
- Lub zog zaus tiv taus qhov hluav taws xob nyob rau hauv kev sim qhuav: 42kV / 5min tsis muaj flashover, tsis muaj puncture.
- Kev tso tawm ib nrab: Tsawg dua lossis sib npaug rau 3pC;
- Txoj kev Creepage: Ntau dua lossis sib npaug li 20mm / kV.
4. Kev teeb tsa thiab kev ua haujlwm
- Thaum kawg ntawm lub npav -bar puag ncig, tsis tso cai rau kev teeb tsa ntawm lub kaum sab xis thiab siv lub qhov (socket) Hexagon ntsia hlau kho nws, txhawm rau zam qhov taw tes
tso tawm.
- Kev nthuav qhia thiab kev teeb tsa (daim duab 1), tus neeg siv xaiv qhov loj me ntawm qhov hluav taws xob hluav taws xob txuas ntxiv raws li lub tsheb npav -bar specification thiab tam sim no tus nqi.
- Fasten lub taag tiv tauj thiab tsheb npav -bar mus rau high voltage termimal insert.
- Kho lub spout (raws li qhov loj ntawm lub qhov mounting) ntawm lub switchgear nrog plaub M8 ntsia hlau.
- Muab lub hauv paus haum rau hauv qab ntawm spout thiab hlau phaj ntawm switchgear, ruaj khov.
- Ntxuav spout tom qab installation, thiab ua kom huv si.
5. Daim ntawv ceeb toom rau kev txiav txim
Thov qhia cov qauv khoom, specification, npe, kom muaj nuj nqis thiab hnub xa khoom ntawm kev txiav txim.
Yog koj txaus siab rau Hu rau lub thawv rau KYN28-12, thov hu rau peb txhua lub sijhawm.

Txhim khu kev qha Vacuum Circuit Breakers, Customized rau cov neeg siv khoom thoob ntiaj teb
Kev cob qhia & Pab Pawg Muag Khoom|Ntawm -Tsev xa khoom
12KV / 24KV / 40.5KV nqus Circuit Court breakers & insulating sib dhos
Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd.
Peb qhov chaw nyob
No.1 East Gaoxin Avenue, High-tech Development Zone, Baoji City, Shaanxi Province, Suav teb
Xov tooj
+86 18091767067(WhatsApp/Wechat/Telegram)
E -mail