Cov khoom

VTZ-12M Permanent Magnet High-Explosive Txee Nqus Circuit Court Breaker
2. Kev khiav hauj lwm Mechanism: Permanent magnetic operating mechanism.
3. Txoj Kev Txhim Kho: Txhim kho kev teeb tsa lossis hloov mus rau lub tsheb thauj khoom-mounted installation.
4. Compatible Txee: Tau tshaj ntau yam switchgear.
5. Cov khoom ua raws li cov qauv: GB/T1984-2014, GB/T11022-2011.
6. Cov Khoom Zoo: E2-C2-M2 kev ua tau zoo, kev pab lub neej ntev, kev ntseeg siab, siab conductivity, ceev qhib ceev, dav siv tau.
VTZ-12M Permanent Magnet High-Explosive Cabinet Vacuum Circuit Breaker (Tongzhong Electric Special Model) yog lub tshuab nqus tsev vacuum rau underground mining applications rated ntawm 12kV, 50/60Hz AC. Featuring lub tshuab hlau nplaum tas mus li, nws muaj kev pab cuam lub neej ntev thiab sib txuas ua ke ua - hauv kev siv tshuab kaw lus thiab ua haujlwm tsis zoo. Nyob rau hauv qhov xwm txheej ntawm cov hlau nplaum ruaj khov tswj tsis ua haujlwm, cov kev ua haujlwm ntawm kev siv tshuab ua kom muaj zog thaum muaj xwm txheej ceev thiab kaw cov txheej txheem. Haum rau txhua qhov chaw uas yuav tsum tau tawg- pov thawj cov khoom siv hluav taws xob, qhov kos- tawm tsev yog sib xws nrog ntau yam mining- qib siab-voltage explosion-proof switchgear txee.
Khoom Specifications
Specification Sheet
|
Tsis muaj. |
Lub npe |
Chav tsev |
Cov ntaub ntawv |
|
1 |
Rated Voltage |
kV ua |
12 |
|
2 |
Rated Zaus |
Hz |
50/60 |
|
3 |
RatedCurrent |
A |
630/1250 |
|
4 |
RatedPtus tswv Fkev xav tauWtivVoltage |
kV ua |
48(Common value) /42(Ntawm kev sib cais nrug) |
|
5 |
RatedLightnhauvImpulseWtivVoltage |
kV ua |
75 (Common tus nqi) / 85 (Ntawm qhov kev ncua deb) |
|
6 |
RatedShort -Circuit uaBreakingCurrent |
kA |
25/31.5 |
|
7 |
Rated Short -Circuit uaMkevCurrent (Peak) |
kA |
63/80 |
|
8 |
RatedWtivCurrent (Peak) |
kA |
63/80 |
|
9 |
RatedDuration ntawmShort -Circuit ua |
s |
4 |
|
10 |
Kev khiav haujlwmCycles uaRatedShort -Circuit uaBreakingCurrent |
Sijhawm |
E2 |
|
11 |
Neeg kho tshuabEkev ua siab ntev |
Sijhawm |
>20000 |
|
12 |
Kev khiav hauj lwm StandardSsib npaug |
- |
O-0.3s-CO-180s-CO |
|
13 |
Tso cai Wpob ntsegThickness ntawmCtiv |
mm |
Tsawg dua los yog sib npaug 3 |
Neeg kho tshuabCharacteristics
|
Tsis muaj. |
Lub npe |
Chav tsev |
Cov ntaub ntawv |
|
1 |
Clearance ntawmTsiv thiab Kho Ctiv |
mm |
9±1 |
|
2 |
Hu rauHla mus ncig |
mm |
3.5±0.5 |
|
3 |
Nruab nrabCpoobSpeb |
m/s |
0.7±0.2 |
|
4 |
Nruab nrabOpeningSpeb (Anruab nrabSpebntawm First Openingntawm6mm) |
m/s |
1.1±0.2 |
|
5 |
RatedCtivSiab |
N |
2500 ± 200N (25kA) 3100 ± 200N (31.5kA)
|
|
6 |
Lub Sijhawm Kaw |
ms |
Tsawg dua los yog sib npaug50ms ib |
|
7 |
Sijhawm qhib |
ms |
Tsawg dua los yog sib npaug li 50ms ib |
|
8 |
Hu rauBua ounceDuration ntawmCpoobOkev ua txhaum |
ms |
Tsawg dua los yog sib npaug2 |
|
9 |
Tsis yog -SimultaneityntawmKaw/OpeningKev ua haujlwmntawm 3-Phase |
ms |
Tsawg dua los yog sib npaug 2 |
Khoom zoo
VTZ-12M Permanent Magnet High-Explosive Txee Nqus Circuit Breaker muaj ntau yam zoo:
Circuit Breaker Performance: E2-C2-M2
Simplified Maintenance: Siv cov hlau nplaum ruaj khov ua haujlwm rau lub neej ua haujlwm ntev;
Kev nyab xeeb thiab kev ntseeg tau: Nruab nrog phau ntawv kaw thiab tripping li rau thaum muaj xwm ceev fais fab mov / disconnection; txhim khu kev qha mechanical interlocking ntawm Circuit Court breaker thiab txee ua kom muaj kev nyab xeeb ntawm tus neeg teb xov tooj; hluav taws xob chassis enables unattended chaw taws teeb tswj.
High Conductivity: Rational conductive Circuit Court tsim raws li 1.1 npaug ntawm qhov ntsuas kub tam sim no;
Intelligent Configuration:
ib. Kev xaiv tus kheej -powered wireless ntsuas kub ntsuas kev daws teeb meem rau kev nyab xeeb thiab txij nkawm- ua haujlwm dawb;
b. Kev soj ntsuam cov yam ntxwv zoo rau kev daws teeb meem tiag tiag - lub sij hawm taug qab ntawm cov ntaub ntawv kev ua haujlwm ntawm Circuit Court breaker, ua kom pom ntxov ntxov thiab daws cov teeb meem uas muaj peev xwm;
c. Motorized txee nkag kev daws teeb meem rau cov chaw taws teeb ua haujlwm thiab kev ruaj ntseg neeg ua haujlwm;
D. Tiag -Lub sij hawm tiv thaiv kev laus kom paub txog kev ua raws li txoj cai.
Haum rau:
Ntau hom mining tawg- pov thawj switchgear; tshiab modular siab-cov khoom tawg;
Cov khoom siv
VTZ-12M Permanent Magnet High-Explosive Cabinet Vacuum Circuit Breaker muaj ntau daim ntawv thov:
1. Coal mining kev lag luam 2. Hlau mining kev lag luam
Product Outline Drawing

Product Wiring Diagram

Peb tuaj yeem tsim tau ntau yam ntawm mining nqus Circuit Court breaker .Yog xav paub ntxiv, thov hu rau peb.
vim li cas xaiv peb
Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd. yog cov chaw tsim khoom lag luam nrog ntau tshaj 20 xyoo ntawm kev paub, tshwj xeeb hauv kev ua haujlwm siab 7 txog 40.5kV lub tshuab nqus tsev vacuum breakers, switchgears, thiab ntau yam khoom siv hluav taws xob. Peb cov txheej txheem tsim khoom ua tau zoo ua kom ntseeg tau, cov kev daws teeb meem ruaj khov, tshwj xeeb tshaj yog peb cov VTZ series lub tshuab nqus tsev vacuum breakers, uas yog tu- pub dawb txog li 20 xyoo. Nrog ib pab pawg kws tshaj lij, peb ua tau zoo hauv R&D, kev tsim khoom, thiab tom qab- muag kev pabcuam rau cov khoom siv hluav taws xob siab thiab tsis tshua muaj hluav taws xob, xa cov khoom zoo ntawm txhua theem.
Excellence nyob rau hauv kev tshawb fawb thiab kev loj hlob
Innovation yog lub hauv paus ntawm peb txoj kev lag luam. Peb tau tsim tus kheej VTZ Series Nqus Circuit Court Breakers thiab txuas ntxiv mus nqis peev hauv kev tshawb fawb thiab kev tsim kho kom tau raws li cov kev xav tau ntawm kev lag luam hluav taws xob. Peb pab pawg R & D muaj cov kws tshaj lij cov kws tshaj lij nrog ntau xyoo dhau los ntawm kev tsim thiab tsim cov khoom siv hluav taws xob siab thiab tsis tshua muaj hluav taws xob. Lawv cov kev txawj ntse, ua ke nrog peb cov chaw ua haujlwm siab, tso cai rau peb nyob ua ntej ntawm kev lag luam tiam sis thiab txuas ntxiv ua kom zoo dua peb cov khoom muag.
Advanced manufacturing thiab ntau lawm
Peb ua haujlwm ib qho ntawm cov khoom siv siab tshaj plaws thiab cov txheej txheem sib dhos kab tsim khoom hauv kev lag luam, nruab nrog cov thev naus laus zis tshiab, ua rau peb tsim ntau yam khoom siv hluav taws xob zoo nrog precision thiab ua haujlwm zoo. Peb ua raws li GB 1984-2024 thiab GB / T11022-2020 cov qauv los xyuas kom meej qhov zoo tshaj plaws. Peb qhov kev cog lus rau kev ua tau zoo yog pom nyob rau hauv lub durability, kev cia siab, thiab compatibility ntawm peb cov khoom.
Ua raws li kev lag luam tiam sis
Ua raws li peb txoj kev npaj tsim tawm, peb tsis tu ncua hloov peb cov khoom kom ua raws li cov qauv tshiab hauv cov phiaj xwm ntse, lub zog hluav taws xob automation, thiab qhov chaw siab tshaj plaws. Peb cov khoom ua haujlwm siab -tam sim no, siab -voltage, thiab ntev- cov khoom siv lub neej yog tsim los ua kom tau raws li qhov xav tau ntawm cov tshuab hluav taws xob niaj hnub no, muab peb cov neeg siv khoom txhim khu kev qha, kev saib xyuas- cov kev daws teeb meem dawb uas sawv cev rau lub sijhawm.
Ntau yam ntawm cov khoom
Peb muab ntau yam khoom, nrog rau sab hauv tsev thiab sab nraum zoov lub tshuab nqus tsev vacuum breakers, switchgear, tsis tshua muaj hluav taws xob hloov khoom siv, thiab ntau yam khoom siv hluav taws xob. Txhua yam khoom tsim los ua kom tau raws li cov kev xav tau tshwj xeeb ntawm peb cov neeg siv khoom, thiab tuaj yeem ua haujlwm ruaj khov hauv kev sib faib hauv nroog, kev lag luam yaj, kev tsim hluav taws xob tshiab, hluav taws xob nyob deb nroog thiab lwm qhov chaw, thiab tseem tuaj yeem muaj kev ntseeg tau zoo txawm tias nyob hauv ib puag ncig hnyav.
Cim npe nrov: vtz-12m ruaj khov hlau nplaum siab- tawg txee lub tshuab nqus tsev Circuit Court breaker, Tuam Tshoj vtz-12m ruaj khov hlau nplaum high-explosive txee nqus tsev vacuum breaker manufacturers, lwm tus neeg, Hoobkas
-
VTZ-12C Nqus Circuit Court Breaker nrog Lateral Operating...saib ntxiv> -
ZN85-40.5 Miniaturized Nqus Circuit Court Breakersaib ntxiv> -
ZND -12} Mus tas li Sib Nqus Ua Haujlwm Me Me Me Me Me Me...saib ntxiv> -
Vs 1-12 630 Lub tshuab nqus tsev hluav taws xob lub tshua...saib ntxiv> -
Vs 1-24 C nyob sab hauv lub tshuab nqus dejsaib ntxiv> -
Vsm -12 Nyob Sab Hauv Tsev Hlau nplaum Sib Nqus Plua Plav...saib ntxiv>