Vim li cas thiaj muaj kev sib cuam tshuam ntawm ob qho kawg ntawm Circuit Court breaker nyob rau hauv ib qho chaw substation?

Cov hluav taws xob hluav taws xob tau nruab nrog cov kev hloov pauv (feem ntau hu ua "riam keyboards") ntawm ob qho kawg kom ua tiav plaub lub hom phiaj tseem ceeb, suav nrog "kev rho tawm, hauv av, pom meej, thiab yoog raws."

Cia peb tawg lawv hauv kev nthuav dav:

Tsim kom muaj qhov pom tseeb ntawm kev sib txuas ntawm lub cev (Core: Kev sib cais zoo)

 

Cov kev txwv ntawm Circuit Court breakers: Txawm hais tias Circuit Court breakers tuaj yeem cuam tshuam cov load tam sim no thiab luv luv -circuit tam sim no, lawv cov kev sib cuag yog nyob rau hauv, ua rau nws tsis yooj yim sua kom pom los ntawm sab nraud seb lawv puas raug txiav tawm tiag tiag. Txawm tias nyob rau hauv lub xeev "qhib", tej zaum tseem yuav muaj ib tug tsis muaj zog hluav taws xob kev twb kev txuas los yog puas ntsoog txaus ntshai ntawm cov tsiv thiab nyob ruaj ruaj tiv tauj vim yog rwb thaiv tsev degradation, mechanical tsis ua hauj lwm, thiab lwm yam.

Lub luag hauj lwm ntawm riam keyboards: Disconnecting keyboards muaj ib tug yooj yim qauv thiab ib tug kom meej meej pom huab cua rwb thaiv tsev sib txawv thaum disconnected. Qhov kev sib txawv no muab "qhov tseeb ntawm lub cev tsis sib xws," tso cai rau cov neeg ua haujlwm saib xyuas kom pom tseeb tias lub voj voog tau raug cais tawm.

Yog vim li cas rau pem hauv ntej thiab nram qab configuration: Circuit Court breakers yog cov khoom uas yuav tsum tau kho thiab kho. Yog tias tsuas muaj riam hloov ntawm ib sab ntawm lub Circuit Court breaker, lwm sab yuav tseem muaj zog thaum lub Circuit Court breaker raug kho, tsis tsim kom muaj kev nyab xeeb "kev sib cais". Nrog disconnect keyboards ntsia ntawm ob qho kawg, lub Circuit Court breaker yog kiag li cais tawm ntawm lub zog, tsim kom muaj kev nyab xeeb ua haujlwm qhov twg qhov kawg tsis muaj zog.

VS1-12 Vacuum Circuit Breaker with Lateral Operating Mechanism 45℃view
vs1-12 nqus Circuit Court breaker
ZW7-40.5 Vacuum circuit breaker
zw7-40.5 nqus Circuit Court breaker
 
VTZ vacuum circuit breaker
vtz- 12 lub tshuab nqus tsev Circuit Court breaker

 

 

Txhim kho cov cuab yeej tu thiab hauv av (Core: Tiv thaiv tus kheej kev nyab xeeb)

 

Erecting grounding wires: Hauv kev tswj hwm kev nyab xeeb ntawm kev lag luam hluav taws xob, kev txhim khu kev qha hauv av hauv txhua qhov kev taw qhia ntawm lub zog muaj peev xwm yog qhov tseem ceeb tshaj plaws los tiv thaiv lub neej ntawm cov neeg ua haujlwm tu. Qhov hloov hauv av (lossis lwm qhov hloov hauv av) ntawm qhov hloov pauv yog siv rau lub hom phiaj no.

 

Cov txheej txheem: Thaum nws yog ib qho tsim nyog los tswj lub Circuit Court breaker los yog kab, kev khiav hauj lwm ib ntus feem ntau:

1. Qhib lub Circuit Court breaker.

2. Disconnect tus disconnect hloov ntawm kab sab.

3. Disconnect tus disconnect hloov ntawm lub busbar sab.

4. Lub sijhawm no, ob sab ntawm lub Circuit Court breaker raug cais tawm ntawm lub zog hluav taws xob.

5. Kaw cov kab - sab hauv av hloov (grounding sab kab).

6. Kaw lub busbar -sab grounding switch (grounding the busbar side).

 

Qhov tseem ceeb: Qhov no ua kom ntseeg tau tias txawm tias ib tus neeg yuam kev kaw qhov kev sib txuas ntawm ob sab ntawm lub tshuab hluav taws xob, lossis yog tias qhov hluav taws xob raug tsim tawm hauv kab, tam sim no yuav raug coj mus rau hauv av, yog li lav kev nyab xeeb ntawm cov neeg ua haujlwm tu. Yog tias tsis muaj qhov hloov pauv thiab kev ua haujlwm hauv av ntawm ob sab, qhov kev txhim khu kev qha thiab kev nyab xeeb tsis tuaj yeem ua tiav.

Hloov cov kev khiav hauj lwm hom los txhim kho lub hwj chim mov kev ntseeg tau

 

Hloov cov kev khiav hauj lwm hom los txhim kho cov khoom siv hluav taws xob muaj kev ntseeg siab (Core: Kev ua haujlwm yooj yim) Substation busbars thiab kab kuj yuav tsum tau saib xyuas. Los ntawm configuring pem hauv ntej thiab nram qab disconnect keyboards, hloov pauv hloov tau ua tiav, txo qhov peev xwm ntawm hluav taws xob tawm.

 

Kev saib xyuas Busbar: Thaum ib ntu ntawm busbar xav tau kev saib xyuas, tag nrho cov kab hluav taws xob txuas nrog lub busbar tuaj yeem hloov mus rau lwm lub busbar ib txwm los ntawm kev ua haujlwm "busbar switching", ua tiav busbar de- energization yam tsis cuam tshuam cov load. Qhov no yuav tsum muaj kev sib koom ua haujlwm ntawm kev sib txuas ntawm ob sab ntawm lub Circuit Court breaker.

 

Kev saib xyuas Circuit Court breaker: Thaum lub Circuit Court breaker nws tus kheej xav tau kev saib xyuas, lub bypass busbar (yog tias muaj) thiab bypass Circuit Court breaker tuaj yeem siv. Los ntawm kev khiav hauj lwm cov kev hloov pauv, lub load tuaj yeem hloov mus rau lub bypass Circuit Court breaker, ua tiav "circuit breaker txij nkawm yam tsis cuam tshuam cov kab hluav taws xob." Qhov no kuj tso siab rau kev ua tib zoo teeb tsa ntawm kev txiav cov keyboards.

 

zw32 vacuum circuit breaker

Tsim kom muaj kev khiav hauj lwm meej meej (Kev Tiv Thaiv Kev Sib Tham Sib Tham)

 

Kev ua haujlwm hluav taws xob tau nruj "tsib-kev tiv thaiv", ib qho tseem ceeb tshaj plaws yog "tiv thaiv kev ua haujlwm ntawm kev sib txuas ntawm cov keyboards hauv qab load."

 

Disconnect keyboards tsis muaj arc - tua muaj peev xwm thiab yuav tsum tsis txhob ua haujlwm tam sim no. Lub xub ntiag ntawm lub Circuit Court breaker muab kev ruaj ntseg lav rau kev khiav hauj lwm lub disconnect hloov.

Tus qauv hluav taws xob hluav taws xob ua haujlwm ua ntu zus yog: thawj zaug qhib lub Circuit Court breaker → ces qhib lub load- sab disconnect hloov → thaum kawg qhib lub hwj chim - sab disconnect hloov.

 

Lub hwj chim kho kom rov ua haujlwm ua ntu zus yog qhov thim rov qab: thawj zaug kaw lub hwj chim - sab disconnect hloov → ces kaw lub load - sab disconnect hloov → thaum kawg kaw lub Circuit Court breaker.

 

Qhov no "circuit breaker-disconnect switch-disconnect switch" qauv, nyob rau hauv cov nqe lus ntawm hluav taws xob interlocking thiab kev khiav hauj lwm daim pib system, tswj kom meej thiab muaj kev ruaj ntseg cov txheej txheem, zoo heev txo txoj kev pheej hmoo ntawm kev ua yuam kev.

Piv txwv thiab Analogy

Xav txog tej yam khoom siv hauv koj lub tsev (xws li lub tshuab cua txias):

Lub Circuit Court breaker yog zoo li lub tshuab cua txias tswj chaw taws teeb, tso cai rau koj kom yooj yim tig lub tshuab cua txias rau thiab tawm (kev ua haujlwm hauv qab).

Lub disconnect hloov yog zoo li lub qhov (socket) phab ntsa. Thaum koj yuav tsum tau ntxuav lub hauv paus ntawm koj lub tshuab cua txias lossis ua haujlwm, tsuas yog tig nws nrog cov chaw taws teeb tswj tsis muaj kev nyab xeeb. Koj yuav tsum unplug nws los tsim ib tug pom, lub cev disconnect point los xyuas kom meej kev ruaj ntseg.

Pem hauv ntej thiab nram qab disconnect keyboards yog zoo li muaj ib tug plug nyob rau hauv txhua kawg ntawm lub tshuab cua txias lub hwj chim qaum, ntsaws rau hauv lub qhov (socket) phab ntsa thiab lub qhov (socket) cua txias. Qhov no tso cai rau koj kom muaj kev nyab xeeb thiab cais tawm ntawm lub tshuab cua txias (circuit breaker) ntawm qhov system.

Hauv cov ntsiab lus

 

Kev teeb tsa ntawm kev hloov pauv ntawm ob qho kawg ntawm lub chaw nres tsheb hluav taws xob hluav taws xob yog qhov tseem ceeb ntawm lub zog hluav taws xob "kev nyab xeeb ua ntej" thiab "txhim kho lub zog hluav taws xob" cov qauv tsim. Nws lub luag haujlwm tseem ceeb yog:

 

1. Kev sib cais kev nyab xeeb: Tsim kom pom thiab txhim khu kev qha hluav taws xob cais qhov taw qhia rau kev saib xyuas.

2. Kev nyab xeeb hauv av: Muab kev tiv thaiv av txhim khu kev qha rau thaj chaw tu kom tsis txhob muaj hluav taws xob poob.

3. Kev ua haujlwm yooj yim: Txhawb ntau yam kev hloov pauv, txo qhov kev siv hluav taws xob, thiab txhim kho kev ntseeg tau.

4. Sequential interlocking: Ua kom muaj kev nyab xeeb ntawm kev ua haujlwm kom tsis txhob ua yuam kev.

Qhov no yog tus qauv tsim thiab yuav tsum muaj kev ruaj ntseg teeb tsa tsim los ntawm kev siv sijhawm ntev - nyob rau hauv lub hwj chim system.

zW32-12 sab nraum zoov lub tshuab nqus tsev Circuit Court breaker

 

 

 

ZW32-12 Sab nraum zoov Nqus Circuit Court Breaker (tom qab no hu ua "circuit breaker") yog peb -theem AC 50Hz sab nraum zoov high voltage switchgear feem ntau yog siv nyob rau hauv 10kV sab nraum zoov tis systems ntawm cov nyob deb nroog thiab nroog, raws li ib tug txhais tau tias ntawm tawg thiab kaw load tam sim no, overload tam sim no, thiab luv luv -circuit tam sim no; Nws kuj tseem tuaj yeem siv rau hauv lwm qhov chaw zoo sib xws; Cov yam ntxwv ntawm cov qauv: Lub Circuit Court breaker muaj peb - theem pillars thiab ib qho kev khiav hauj lwm mechanism, nrog ib tug yooj yim qauv. Tus ncej txais epoxy resin khoom rwb thaiv tsev, uas muaj qhov zoo ntawm qhov kub thiab txias tsis kam, UV tsis kam, thiab kev laus ua haujlwm; Circuit Court breaker kev ua tau zoo: E2-C2-M2.

 

ZW32-12 Sab Nraum Nqus Circuit Court Breaker muaj ntau yam zoo:

 

1.Main kev ua tau zoo tom qab txuas lwm yam khoom siv:

1) Sab nraum zoov rho tawm hloov thiab Circuit Court breaker tuaj yeem ntsia tau rau hauv lub cev, Circuit Court breaker thiab kev rho tawm hloov pauv muaj qhov cuam tshuam txhim khu kev qha, nrog rau kev tiv thaiv - ua haujlwm tsis raug.

2) tuaj yeem ntsia tau nrog cov khoom siv hluav taws xob sab nraud PT, kom lub tshuab hluav taws xob muaj lub zog ua haujlwm thiab muaj kev tiv thaiv - surge tam sim no, tiv thaiv overcurrent, nyob ze rau cov chaw taws teeb tswj kev ua haujlwm.

3) Lub ntes tuaj yeem ntsia tau, thiab tus neeg ntes tuaj yeem ntsia tau rau ntawm lub hwj chim sab lossis sab load raws li qhov xav tau ntawm tus neeg siv.

4) tuaj yeem ua ke nrog cov khoom siv hluav taws xob faib khoom siv hluav taws xob los tsim cov khoom siv hluav taws xob sab nraum zoov, ntu ntu, cov khoom siv tswj xyuas ntse.

5) tuaj yeem siv nrog cov kab hloov pauv cov chaw taws teeb saib xyuas, siv GPRS wireless kev sib txuas lus, kom ua tiav sab nraum zoov Air Circuit Court breaker tej thaj chaw deb tiag tiag - lub sijhawm saib xyuas, kom ua tau raws li qhov xav tau ntawm kev faib khoom siv hluav taws xob.

 

2.Wide ntau yam ntawm kev siv: hloov mus rau qhov hnyav ib puag ncig, cov khoom tuaj yeem tiv taus qhov kub qis dua 25 degree. Ua tau raws li 2000m altitude yuav tsum. Raws li cov kev cai tshwj xeeb, qhov tsawg kawg nkaus tuaj yeem ncav cuag -40 degree, thiab cov kev cai tshwj xeeb tuaj yeem ua tau raws li qhov siab ntawm 4000 meters.

tiv tauj peb

 