Cov roj hluav taws xob hluav taws xob thiab lub tshuab nqus hluav taws xob yog ob hom hluav taws xob hluav taws xob feem ntau siv hauv cov tshuab hluav taws xob. Lawv muaj qhov sib txawv tseem ceeb hauv arc extinguishing media, cov yam ntxwv ntawm cov qauv, thiab cov xwm txheej siv tau.
1. Cov qauv thiab ntim
Roj Circuit Court breaker:
Cov qauv yog complex, yuav tsum tau ib tug roj tank, roj theem xyuas cov cuab yeej thiab lub siab nyem mechanism, thiab lub ntim yog loj.
Lub tshuab nqus tsev Circuit Court breaker:
Lub arc extinguishing chamber yog lub kaw ntom nti ceramic lossis iav qauv, nrog lub ntim me me thiab lub teeb yuag, haum rau compact switchgear (xws li nruab nrab -voltage switchgear).
2. Kev tu thiab lub neej Roj Circuit Court breaker:
Tom qab kev sib cuag yog hnav, cov roj yuav tsum tau hloov thiab cov carbide yuav tsum tau ntxuav.
Lub tshuab nqus tsev Circuit Court breaker:
Lub tshuab nqus tsev arc extinguishing chamber raug kaw thiab pib txij nkawm- dawb.
Kev sib tiv tauj yog me me, thiab lub neej muaj peev xwm ncav cuag kaum tawm txhiab txoj haujlwm.
3. Kev ua haujlwm hluav taws xob
Breaking peev:
Lub tshuab nqus tsev vacuum muaj lub zog luv luv - lub peev xwm tawg tam sim no (tshwj xeeb yog tsim rau nruab nrab qhov hluav taws xob, xws li 10-35 kV).
Cov roj hluav taws xob hluav taws xob muaj feem cuam tshuam rau kev kav thaum tawg cov dej loj.
Rwb thaiv tsev zog:
Lub zog rwb thaiv tsev ntawm lub tshuab nqus tsev nruab nrab yog ntau dua li ntawm cov roj nruab nrab, thiab qhov kev rov qab tau nrawm dua.
4. Daim ntawv thov scenarios
Roj Circuit Court breakers:
Cov tshuab hluav taws xob ib txwm siv (xws li cov chaw qub qub), sab nraum zoov siab - lub sijhawm hluav taws xob (xws li siab dua 110 kV).
Maj mam hloov los ntawm SF₆ lossis lub tshuab nqus tsev vacuum.
Nqus Circuit Court breakers:
Dominated los ntawm nruab nrab voltage teb (6-40 kV), xws li kev faib tes hauj lwm, muaj hluav taws xob, tsheb thauj mus los, thiab lwm yam.
Siab - zaus ua haujlwm zaus (xws li arc rauv, tswj lub cev muaj zog).
5. Kev tiv thaiv ib puag ncig
Roj Circuit Court breakers:
Cov roj insulating tuaj yeem xau thiab paug cov av lossis dej.
Nqus Circuit Court breakers:
Tsis muaj kuab paug, raws li cov qauv kev tiv thaiv ib puag ncig niaj hnub.
VTZ-12F generator tso zis tshwj xeeb lub tshuab nqus tsev Circuit Court breakerlos ntawmShaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd. yog ib qho hluav taws xob hauv tsev AC lub tshuab hluav taws xob tsim hluav taws xob tsim rau 15kV peb -theem AC tshuab ua haujlwm ntawm 50Hz. Nws yog feem ntau siv nyob rau hauv lub generator tso zis circuits ntawm me me mus rau nruab nrab hydroelectric fais fab nroj tsuag, thermal fais fab nroj tsuag, lub zog tshiab lub zog tsim units, thiab industrial circuits nrog tus kheej - muaj hwj chim mov, xws li cov nyob rau hauv cov tshuaj thiab kev lag luam.
VTZ-12F generator tso zis tshwj xeeb lub tshuab nqus tsev Circuit Court breaker muaj ntau yam nta:
1.High tam sim no muaj peev xwm, siab tawg muaj peev xwm, advanced kev ua tau zoo, thiab superior manufacturing zoo.
2.Lub DC tivthaiv ntawm qhov ntsuas luv luv-circuit breaking tam sim no ntau dua los yog sib npaug li 75%.Adopts ib tug kev khiav hauj lwm mechanism.Thaum ntsia ib tug neeg, cov ntsuas tam sim no muaj peev xwm ncav cuag 6300A nrog ntuj cua txias, thiab mus txog 8000A nrog yuam cua txias.
3.Insulation siv tus ntoo khaub lig elliptical-section tsim kom tau raws li tensile thiab dabtsi yog khoov lub zog yuav tsum tau, siv high-lub zog insulating rub rods thiab txhawb rods.
4.Grading rings yog tsim los ntawm cov insulators thiab kev txhawb nqa kom ntseeg tau tias cov khoom siv hluav taws xob tsis sib xws.
5.Lub Circuit Court breaker siv ib txoj kev txhim kho ruaj khov, thiab lub ntsiab Circuit Court ua tau raws li qhov yuav tsum tau ua ntawm kev rwb thaiv tsev nyob deb.
VTZ-12F generator tso zis tshwj xeeb lub tshuab nqus tsev Circuit Court breaker tuaj yeem siv rau Generators,
Main circuits ntawm theem shifters, pumped -storage fais fab nroj tsuag
thiab Utility circuits nyob rau hauv me me thiab nruab nrab - muaj peev xwm fais fab nroj tsuag.