Blog

Home/Blog/Paub meej

Cov khoom siv hluav taws xob theem nrab yog dab tsi?

Cov khoom siv hluav taws xob thib ob yog hais txog cov khoom siv hluav taws xob qis qis uas siv los saib xyuas, tswj, tswj, thiab tiv thaiv cov cuab yeej tseem ceeb (xws li lub tshuab hluav taws xob, hloov hluav taws xob, hluav taws xob hluav taws xob, thiab lwm yam), thiab muab cov kev ua haujlwm lossis cov lus txib tsim khoom rau cov neeg ua haujlwm thiab tu cov neeg ua haujlwm.

Yog tias cov cuab yeej tseem ceeb ncaj qha rau hauv kev tsim hluav taws xob thiab kev sib kis yog "pob txha thiab cov leeg" ntawm lub zog hluav taws xob, cov khoom siv hluav taws xob theem nrab yog nws "neural network" thiab "ntse hauv nruab nrab hub." Nws tsis ncaj qha koom rau hauv siab - tam sim no kis tau tus mob ntawm lub ntsiab Circuit Court, tab sis nws ua kom muaj kev nyab xeeb, txhim khu kev qha, thiab kev lag luam ntawm cov khoom siv tseem ceeb los ntawm cov hluav taws xob tsawg -voltage circuits.

 

Kev faib cov khoom siv thib ob

 
 

Kev ntsuas thiab ntsuas cov cuab yeej: xws li ammeters, voltmeters, wattmeters, thiab lub zog ntsuas hluav taws xob, siv los qhia thiab sau cov kev ua haujlwm ntawm cov thawj qhov system hauv lub sijhawm.

 

Kev tiv thaiv relay thiab cov khoom siv tsis siv neeg: xws li ntau yam kev tiv thaiv relay, cov cuab yeej kaw tsis raug, thiab cov khoom siv rov qab tsis siv neeg. Lawv tuaj yeem hnov ​​​​mob sai sai thaum muaj qhov ua txhaum cai tshwm sim, cais qhov txhaum lossis rov ua kom lub zog rov qab.

 

Tswj thiab taw qhia cov khoom siv: xws li kev tswj cov keyboards, cov nyees khawm, qhov taw qhia teeb, thiab cov khoom siv lub tswb nrov (tswj, sirens), siv rau kev ua haujlwm ntawm cov chaw taws teeb ntawm cov cuab yeej tseem ceeb thiab kev tawm tswv yim ntawm nws txoj haujlwm ua haujlwm.

 

Cov cuab yeej transformers: suav nrog tam sim no transformers (CTs) thiab voltage transformers (PTs). Lawv ua raws li "bridges" txuas cov thawj thiab theem nrab systems, proportionally converting high voltage thiab high tam sim no nyob rau hauv thawj sab mus rau hauv tus qauv uas tsis muaj voltage thiab tsis tshua muaj tam sim no nyob rau hauv lub thib ob sab rau siv los ntsuas thiab tiv thaiv cov khoom.

lvzw-35-current-transformer

 

Kev khiav hauj lwm fais fab mov: suav nrog DC fais fab mov systems (xws li roj teeb lub tsev txhab nyiaj thiab rectifiers) thiab AC fais fab mov systems, muab ib tug ruaj khov thiab txhim khu kev qha fais fab mov rau kev tswj, kev tiv thaiv, thiab cov khoom siv teeb liab.

 

Kev sib txuas thiab cov cuab yeej pabcuam: xws li kev tswj cov cables, txuas cov xov hlau, lub davhlau ya nyob twg, fuses, thiab lwm yam, siv los txuas cov khoom siv saum toj no rau hauv ib qho hluav taws xob ua tiav.

 

Cov hluav taws xob hluav taws xob tsim los ntawm kev sib cuam tshuam ntawm cov khoom siv thib ob, uas saib xyuas, tswj, tswj, thiab tiv thaiv cov cuab yeej tseem ceeb, yog sib sau ua ke hu ua lub voj voog thib ob (lossis lwm qhov txuas).

 

Hauv cov ntsiab lus

 

Hauv cov ntsiab lus, txawm hais tias cov khoom siv thib ob tsis xa ncaj qha rau cov tam sim no loj lossis cov hluav taws xob siab, nws ua kom muaj kev nyab xeeb ntawm cov cuab yeej tseem ceeb los ntawm kev kaw - voj voog ntawm "sensing- kev txiav txim siab- kev tua," ua qhov tseem ceeb txhawb rau kev txawj ntse thiab automation ntawm lub zog hluav taws xob. Hauv cov chaw ua haujlwm niaj hnub no, cov khoom siv thib ob yog maj mam txhim kho mus rau digitalization (xws li cov khoom siv ntse ntse thiab kev sib koom ua ke), kev sib txuas lus (IEC 61850 raws tu qauv), thiab kev sib koom ua ke (cov cuab yeej tiv thaiv kev hloov pauv ib txwm siv relays).

VTZ-15/T5000-63 sab hauv tsev high-voltage generator Circuit Court breaker

VTZ-15/T5000-63 sab hauv tsev high-voltage generator Circuit Court breakeryog lub tshuab nqus tsev vacuum breaker tsim rau lub tshuab hluav taws xob qhov hluav taws xob hauv 15 kV thiab qis dua, peb -theem AC 50 Hz systems. Nws yog feem ntau siv nyob rau hauv cov nroj tsuag auxiliary circuits ntawm me me mus rau nruab nrab-size hydroelectric generator units, thermal fais fab generators, tshiab zog tsim systems, thiab industrial chaw-xws li cov nyob rau hauv cov tshuaj thiab ua sectors- uas ua hauj lwm nrog lawv tus kheej captive zog tsim muaj peev xwm.

VTZ-15/T5000-63 Indoor High-voltage Generator Circuit Breaker

Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd.

Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd.yog ib lub chaw tsim khoom nrog ntau tshaj 20 xyoo ntawm kev paub, tshwj xeeb hauv kev ua tau zoo ntawm 7 mus rau 40.5kV lub tshuab nqus tsev vacuum breakers, switchgears, thiab ntau yam khoom siv hluav taws xob.

 

Peb cov txheej txheem tsim khoom ua tau zoo ua kom ntseeg tau, cov kev daws teeb meem ruaj khov, tshwj xeeb tshaj yog peb VTZ series lub tshuab nqus tsev vacuum breakers, uas yog tu- pub dawb txog li 20 xyoo. Nrog ib pab pawg kws tshaj lij, peb ua tau zoo hauv R&D, kev tsim khoom, thiab tom qab- muag kev pabcuam rau cov khoom siv hluav taws xob siab thiab tsis tshua muaj hluav taws xob, muab kev ua tau zoo ntawm txhua theem.

Hu rau: Ms.Grace Liu (International Sales Manager)

Txawb: +8618091765882(WhatsApp/Wechat/facebook/telegram)

Email: xdtz04@westpowerelectric.com

25