Kev Nyab Xeeb Ua Ntej: Vim li cas Ob Sab ntawm Circuit Court Breaker xav tau kev cog lus kom zoo thaum tu

Thaum lub sij hawm kho lub zog, kev txhim kho cov kab hauv av ntawm ob sab ntawm cov kab hluav taws xob yog qhov kev ntsuas kev nyab xeeb tseem ceeb rau cov neeg ua haujlwm. Txawm hais tias muaj coob tus xav tias cov cuab yeej ua de- muaj zog tom qab lub zog hluav taws xob tawm mus, qhov kev txiav txim no tsuas yog txiav tawm ntawm txoj kev hluav taws xob tam sim no yam tsis tas yuav tshem tawm cov hluav taws xob txaus ntshai hauv cov khoom siv. Yog li ntawd, thaum lub sij hawm txij nkawm kev khiav hauj lwm, txhim khu kev qha grounding yuav tsum tau siv ib txhij ntawm ob lub hwj chim mov thiab load sab ntawm lub Circuit Court breaker.
What is electrostatic induction in transmission lines?

 

 


Ua ntej, grounding ob sab ntawm lub Circuit Court breaker tuaj yeem tiv thaiv kom tsis txhob muaj zog. Ob sab ntawm lub Circuit Court breaker feem ntau yog txuas nrog ntau qhov sib txawv ntawm lub zog hluav taws xob, xws li lub zog hluav taws xob thiab sab load. Yog tias cov av tau nruab rau ntawm ib sab xwb, sab nraud kuj tseem tuaj yeem ua kom muaj zog vim yog kev ua haujlwm tsis raug, rov qab- noj los ntawm lwm qhov hluav taws xob, lossis kev sib txuas nrog cov khoom siv hluav taws xob xws li photovoltaic thiab lub zog cia.

 

 

Qhov thib ob, cov xaim hauv av pab tshem tawm cov nqi seem thiab induced voltages los ntawm cov khoom siv. Txawm tias tom qab fais fab tuag lawm, high- cov khoom siv hluav taws xob xws li cables, busbars, thiab capacitors tseem tuaj yeem khaws hluav taws xob. Tsis tas li ntawd, electromagnetic induction los ntawm cov khoom siv hluav taws xob nyob ze tuaj yeem tsim hluav taws xob tsis xav txog ntawm lub tshuab hluav taws xob. Kev cog lus hauv av kom zoo muab txoj hauv kev nyab xeeb rau cov voltages ntws mus rau hauv lub ntiaj teb, kom ntseeg tau tias cov cuab yeej tseem nyob ntawm qhov tsis muaj kev nyab xeeb - lub xeev muaj peev xwm.

 


Tsis tas li ntawd, ob lub - sab hauv av tsim kom muaj kev tiv thaiv kev nyab xeeb rau cov neeg ua haujlwm tu. Thaum cov neeg ua haujlwm tshawb xyuas lub arc extinguishing chamber, kev sib cuag, kev sib txuas, lossis lwm yam khoom siv sab hauv ntawm lub Circuit Court breaker, txhua qhov txawv txav uas tsim los ntawm txhua qhov kev taw qhia tuaj yeem raug tso tawm los ntawm cov av hauv av, yog li txo qhov kev pheej hmoo ntawm hluav taws xob poob siab.

 

 

RauLub tshuab nqus tsev Circuit Court breakers(VCBs), txawm hais tias lub tshuab nqus tsev arc extinguishing chamber nthuav tawm kev ua haujlwm zoo ntawm rwb thaiv tsev, cov rwb thaiv tsev ntawm qhov tawg tsis tuaj yeem hloov cov kev ntsuas kev nyab xeeb hauv av. Txheem lub hwj chim- tawm cov txheej txheem, kev txheeb xyuas qhov hluav taws xob, thiab kev ua haujlwm hauv av yog cov kauj ruam tseem ceeb rau kev ua kom ruaj ntseg cov cuab yeej siv.

 

 

Yog li ntawd, qhib lub Circuit Court breaker tsuas yog hloov nws cov kev ua haujlwm, thaum lub hauv paus ob sab muab kev tiv thaiv tiag tiag rau kev saib xyuas kev nyab xeeb. Nrog rau kev txhim kho cov tshuab hluav taws xob niaj hnub no, kev sib txuas hluav taws xob txuas ntxiv mus, thiab cov phiaj xwm ntse, cov kev ntsuas hauv av txhim khu kev qha yuav txuas ntxiv ua lub luag haujlwm tseem ceeb hauv kev ua kom muaj kev nyab xeeb thiab ruaj khov lub zog ua haujlwm.
 
Yog koj xav paub ntxiv txogVS1-12 1250Lub tshuab nqus tsev Circuit Court Breaker nrog Lateral Operating Mechanismthov koj xav tiv tauj peb txhua lub sijhawm.