Lub neej ntev kev pab cuam ntawm lub tshuab nqus tsev Circuit Court breaker txhais tau hais tias cov txiaj ntsig direclty rau cov neeg siv.
Cov nram qab no peb yuav tham txog dab tsi peb tuaj yeem ua kom paub tseeb tias peb VCB muaj lub neej ua haujlwm ntev dua.
1. Nco ntsoov tias koj xaiv cov khoom VCB zoo (Kev xaiv siv ntawm VCB)
Technical specification cov ntaub ntawv sib txuam, cov ntaub ntawv technical suav nrog:
* Rated voltage thiab tam sim no
* Rated luv -circuit breaking tam sim no
* Mechanical thiab hluav taws xob lifespan
2. Nruab VCB tus kws tshaj lij
* Nyeem thiab ua raws li cov lus qhia ntawm VCB cov chaw tsim khoom.
* Xyuas kom meej meej meej thiab nkag mus deb.
* Lub tshuab nqus tsev twj tso kua mis yuav tsum tau muab tso rau hauv qhov chaw uas tsis muaj hluav taws kub, tawg, kev qias neeg, tshuaj lom neeg thiab kev vibration hnyav.
3. Txuj kev ua haujlwm thiab kev saib xyuas
Tshaj li 80% ntawm lub tshuab nqus tsev vacuum breaker tsis ua hauj lwm los ntawm kev khiav hauj lwm mechanism, tsis ua los ntawm lub tshuab nqus tsev cuam tshuam nws tus kheej.
Yog li kev ua haujlwm ntawm kev ua haujlwm machanism tseem ceeb heev, raws li hauv qab no yog qhov koj tuaj yeem ua tau:
* Tswj kom zoo zog ua haujlwm:
* Tsis tu ncua lubrication
* Txheeb xyuas cov fasteners tsis tu ncua
* Ntxuav lub tshuab tsis tu ncua
4. Kev tshuaj xyuas ntawm lub tshuab nqus tsev cuam tshuam: lub tshuab nqus tsev yog qhov tseem ceeb ntawm lub tshuab nqus tsev cuam tshuam.
* Ua lub zog tsis tu ncua ntawm qhov ntsuas hluav taws xob tiv thaiv hluav taws xob (siv cov ntsuas hluav taws xob zaus tiv thaiv hluav taws xob hla lub sijhawm so rau 1 feeb; dhau yam tsis muaj flashover lossis tawg).
* Siv lub tshuab nqus tsev vacuum magnetron rau kev ntsuas qhov tseeb.
* Saib xyuas qhov tso cai hnav tuab ntawm kev sib cuag tsis tu ncua
5. Kev tshuaj xyuas lub tshuab nqus tsev Circuit Court breaker
* Tsis tu ncua ntsuas lub ntsiab Circuit Court kuj, xyuas kom meej tias qhov kev tiv thaiv tus nqi ruaj khov, yog tias qhov kev tiv thaiv ntau tshaj 150% ntawm lub Hoobkas nqi, yuav tsum tau ua kom sai.
* Kev ntsuas kub infrared: Tsis tu ncua ntsuas cov khoom nkag thiab tawm thiab cov kev sib txuas ntawm busbar nrog lub thermal imager txhawm rau txheeb xyuas qhov muaj peev xwm kub dhau.
XDTZ tsim ZN65-12 lub tshuab nqus tsev vacuum tshwj xeeb tshaj yog haum rau cov chaw ua haujlwm nquag.
ZN65-12 yog peb kab lus 12Kv, 50Hz, (tseem siv rau 60Hz) sab hauv tsev fais fab kis tau tus mob thiab cov khoom siv xa tawm, uas tuaj yeem ntsia tau rau hauv cov khoom siv hloov pauv xws li hloov pauv hloov pauv, tshem tawm cov hloov pauv, thiab qhov chaw hloov pauv.
ZN65-12 yog tsim rau cov khoom siv hluav taws xob thiab cov chaw xa khoom ntawm hluav taws xob, metallurgy, tshuaj lom neeg kev lag luam, mining, cov tsev siab siab, thiab lwm yam lag luam thiab cov chaw ua haujlwm tswj thiab tiv thaiv cov khoom siv hluav taws xob, kuj tuaj yeem siv rau lub sijhawm tshwj xeeb xws li lub txhab nyiaj capacitor.
ZN65-12 yog qhov tshwj xeeb tshaj yog tsim rau cov chaw uas muaj kev ua haujlwm tsis tu ncua thiab kev saib xyuas mus sij hawm ntev.
Lub neej txhua yam yog siab li 30,000 lub voj voog, uas yog tshwj xeeb tshaj yog haum rau cov chaw ua haujlwm nquag

Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd.