1. Nco ntsoov tias koj xaiv cov khoom VCB zoo(Kev xaiv siv ntawm VCB)

 

Technical specification cov ntaub ntawv sib txuam, cov ntaub ntawv technical suav nrog:
* Rated voltage thiab tam sim no
* Rated luv - Circuit Court breaking tam sim no
* Mechanical thiab hluav taws xob lifespan

 

 

2. Nruab VCB tus kws tshaj lij


* Ua tib zoo nyeem thiab ua raws li VCB cov chaw tsim khoom cov lus qhia.
* Xyuas kom meej meej meej thiab nkag mus deb.
* Lub tshuab nqus tsev twj tso kua mis yuav tsum tau muab tso rau hauv qhov chaw uas tsis muaj hluav taws kub, tawg, kev qias neeg, tshuaj lom neeg thiab kev vibration hnyav. 

 

 

3. Txuj kev ua haujlwm thiab kev saib xyuas


Tshaj li 80% ntawm lub tshuab nqus tsev vacuum breaker ua tsis tiav los ntawm kev khiav hauj lwm mechanism, tsis ua los ntawm lub tshuab nqus tsev cuam tshuam nws tus kheej.

Yog li kev ua haujlwm ntawm kev ua haujlwm machanism tseem ceeb heev, raws li hauv qab no yog qhov koj tuaj yeem ua tau:

* Tswj kom zoo zog ua haujlwm:
* Tsis tu ncua lubrication
* Txheeb xyuas cov fasteners tsis tu ncua
* Ntxuav lub tshuab tsis tu ncua

 

 

4. Kev tshuaj xyuas ntawm lub tshuab nqus tsev cuam tshuam: lub tshuab nqus tsev yog qhov tseem ceeb ntawm lub tshuab nqus tsev cuam tshuam.

 

 

* Ua lub zog tsis tu ncua ntawm qhov ntsuas hluav taws xob tiv thaiv hluav taws xob (siv cov ntsuas hluav taws xob zaus tiv thaiv hluav taws xob hla lub sijhawm so rau 1 feeb; dhau yam tsis muaj flashover lossis tawg).

 

* Siv lub tshuab nqus tsev vacuum magnetron rau kev ntsuas qhov tseeb.

 

* Saib xyuas qhov tso cai hnav tuab ntawm kev sib cuag tsis tu ncua

 

 

5. Kev tshuaj xyuas lub tshuab nqus tsev Circuit Court breaker


* Tsis tu ncua ntsuas lub ntsiab Circuit Court kuj, xyuas kom meej tias qhov kev tiv thaiv tus nqi ruaj khov, yog tias qhov kev tiv thaiv ntau tshaj 150% ntawm lub Hoobkas nqi, yuav tsum tau ua kom sai.

 

* Kev ntsuas kub infrared: Tsis tu ncua ntsuas cov khoom nkag thiab tawm thiab cov kev sib txuas ntawm busbar nrog lub thermal imager txhawm rau txheeb xyuas qhov muaj peev xwm kub dhau.

 

 

 

Khoom Description

 

 

 

 

How to Extend The Service Life of a Vacuum Circuit Breaker?

LW25-126 Sab nraum zoov High Voltage Porcelain SF6 Circuit Breaker
 

1. Rated voltage: 126kV
2. SF6 roj: zoo arc extinguishing kev ua tau zoo.
3. Kev Ua Raws Cai: GB/T1984-2014
4. Cov khoom lag luam zoo: muaj peev xwm tawg tau zoo dua, txhim khu kev qha rwb thaiv tsev, thiab kev saib xyuas tsawg.

 

 

 

tuam txhab Taw Qhia

 

 

 

Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd.

Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd. yog cov chaw tsim khoom lag luam nrog ntau tshaj 20 xyoo ntawm kev paub, tshwj xeeb hauv kev ua haujlwm siab 7 txog 40.5kV lub tshuab nqus tsev vacuum breakers, switchgears, thiab ntau yam khoom siv hluav taws xob. Peb cov txheej txheem tsim khoom ua tau zoo ua kom ntseeg tau, cov kev daws teeb meem ruaj khov, tshwj xeeb tshaj yog peb cov VTZ series lub tshuab nqus tsev vacuum breakers, uas yog tu- pub dawb txog li 20 xyoo. Nrog ib pab pawg kws tshaj lij, peb ua tau zoo hauv R&D, kev tsim khoom, thiab tom qab- muag kev pabcuam rau cov khoom siv hluav taws xob siab thiab tsis tshua muaj hluav taws xob, xa cov khoom zoo ntawm txhua theem.

Pab neeg tshaj lij

Peb pab pawg R & D muaj cov kws tshaj lij cov kws tshaj lij nrog ntau xyoo dhau los ntawm kev tsim thiab tsim cov khoom siv hluav taws xob siab thiab tsis tshua muaj hluav taws xob.

Tom qab- muag thiab Kev Pabcuam

Peb tau cog lus tias yuav muab qhov tshwj xeeb tom qab- muag kev txhawb nqa rau peb cov neeg siv khoom thoob ntiaj teb. Peb cov kev pabcuam suav nrog kev txhawb nqa thoob ntiaj teb thiab kev lav phib xaub, xws li kev txhawb nqa hauv online chaw taws teeb, kev cob qhia video, thiab ntawm - kev taw qhia kev teeb tsa hauv chaw.

xdtz

 

Tiv tauj peb

 

logo

Hu rau: Ms.Melody

Email: xdtz03@westpowerelectric.com

Tel: +86 180 9176 5658 (WhatsApp)

LinkedIN