Thaum xaiv qhov tsis yog -brandedLub tshuab nqus tsev Circuit Court breaker-uas tsis muaj kev pom zoo rau cov npe khoom lag luam- nws yog ib qho tseem ceeb uas yuav tsum tau ua qhov kev ntsuam xyuas nruj raws li cov yam ntxwv xws li cov khoom siv, hom qauv, thiab cov txheej txheem yuav khoom. Lub ntsiab lus tseem ceeb nyob rau hauv kev xaiv cov qauv tsim nyog thiab cov lus qhia tshwj xeeb raws li cov ntawv thov tshwj xeeb thiab cov khoom siv hluav taws xob, kom ntseeg tau tias cov cuab yeej ua tau raws li cov qauv kev ua haujlwm rau kev ruaj ntseg thiab kev nyab xeeb.
1. Txiav txim siab cov txheej txheem yooj yim
Qhov no yog lub hauv paus rau kev xaiv ib qho Circuit Court breaker; koj yuav tsum xyuas kom meej tias cov khoom siv tau xaiv tuaj yeem tiv taus ob qho tib si kev ua haujlwm hauv Circuit Court thiab ua txhaum cai.
Kev xaiv los ntawm qhov hluav taws xob: Lub Circuit Court breaker qhov ntsuas hluav taws xob yuav tsum tsis txhob qis dua qhov system lub nominal voltage rau lub Circuit Court, thiab nws qhov siab tshaj plaws kev tso cai ua haujlwm voltage yuav tsum siab tshaj los yog sib npaug rau lub Circuit Court qhov siab tshaj plaws kev khiav hauj lwm voltage.
Kev xaiv los ntawm tam sim no: Lub Circuit Court breaker qhov ntsuas tam sim no (In) yuav tsum siab dua lossis sib npaug ntawm lub voj voog kev khiav hauj lwm tam sim no (Ig) nyob rau hauv ntau hom kev khiav hauj lwm.
Kev xaiv raws li kev khiav haujlwm:
Ambient kub: Xav txog qhov ntsuas kub ntawm cov cuab yeej ua haujlwm ib puag ncig.
Kev txheeb xyuas kev ruaj ntseg: Tshawb xyuas lub Circuit Court breaker kev ruaj ntseg raws li kev ua haujlwm.
2. Xaiv cov qauv raws li hom switchgear
Hom switchgear ncaj qha txiav txim siab uas cov qauv siv hluav taws xob tuaj yeem siv tau.
Nyob sab hauv tsev ruaj khov- hom 10kV switchgear: ZN28 qauv lub tshuab nqus tsev tuaj yeem siv tau; nws yog feem ntau nruab nrog lub caij nplooj ntoos hlav kev ua haujlwm mechanism thiab txhawb AC / DC hluav taws xob nrog rau kev tuav haujlwm.
Sab hauv tsev tshem tau - hom 10kV switchgear (piv txwv li, hom KYN): VS1 qauv lub tshuab nqus tsev hloov tau siv tau; Nws yog feem ntau nruab nrog lub caij nplooj ntoos hlav kev ua haujlwm sib xyaw ua ke thiab tseem txhawb nqa AC / DC hluav taws xob thiab kev tuav haujlwm.
3. Ua raws li kev yuav khoom kom zoo
Kev ceev faj ntsuas thaum lub sijhawm yuav khoom tuaj yeem txo cov kev pheej hmoo zoo.
Kev sim ua haujlwm: Thaum xa khoom, sim txhua qhov haujlwm tseem ceeb ntawm lub Circuit Court breaker thiab ua ib qho kev sim luv luv kom ntseeg tau tias nws ua haujlwm zoo.
Txheeb xyuas cov ntaub ntawv: Ua tib zoo xyuas cov qauv cov ntaub ntawv ntawm daim ntawv xa nyiaj kom tsis txhob yuav cov khoom tsis raug vim muaj qhov sib xws ntawm tus lej qauv txawm tias tus nqi sib txawv tseem ceeb. Rau siab - tus nqi lossis ntau qhov kev yuav khoom, qhov tseeb ntawm cov ntaub ntawv xa nyiaj yog qhov tseem ceeb rau kev saib xyuas yav tom ntej lossis rov qab los. Qhia meej tom qab- nqe lus muag: Ua ntej yuav khoom, nco ntsoov nug tus neeg muag khoom kom paub meej meej txog cov khoom lag luam txoj cai lav, lub sijhawm lav, thiab cov txheej txheem rau kev daws teeb meem.

Txhim khu kev qha Vacuum Circuit Breakers, Customized rau cov neeg siv khoom thoob ntiaj teb
Kev cob qhia & Pab Pawg Muag Khoom|Nyob rau -Tsev xa tuaj
12KV / 24KV / 40.5KV lub tshuab nqus tsev Circuit Court breakers
Shaanxi West Fais Fab Tongzhong Hluav Taws Xob Co., Ltd.
Peb qhov chaw nyob
No.1 East Gaoxin Avenue, High-tech Development Zone, Baoji City, Shaanxi Province, Suav teb
Xov tooj
+86 18091767067(WhatsApp / Wechat)
E -mail